STEREO audio (TV)
Equipment:
Oscilloscope, MTS/SAP Signal Generator
1. Set to TV mode, and then set to STEREO audio.
2. Connect the RF OUTPUT of the MTS/SAP Signal Generator to the
Antenna Input Terminal.
Then, set the MTS/SAP Signal Generator as follows.
MTS (ONLY L CH)
300 Hz±5 Hz
14% or 7% Modulating
3. Connect the Oscilloscope to TP9001 on the Audio C.B.A.
4. Adjust R9001 (SEP (L) ) on the Audio C.B.A. so that the signal level
of TP9001 is minimum.
5. Set the MTS/SAP Signal Generator as follows.
MTS (ONLY L CH)
3 kHz±5 Hz
14% or 7% Modulating
6. Adjust R9008 (SEP (H) ) on the Audio C.B.A. so that the signal
level of TP9001 is minimum.
Fig. E2
7.3.4. SEPARATION ADJUSTMENT (MODEL: D, E)
Note:
Be sure to perform this adjustment after STEREO/SAP
SEPARATION ADJUSTMENT are completed.
Purpose:
To separate the L and R Channels of Stereo Signal.