2. Set the Default value of all Control functions using a remote
control as shown in "Memory IC Reference Table."
Note:
For Selecting Control functions and setting Default value, refer to "
HOW TO ENTER EVR ADJUSTMENT MODE
" and "
HOW TO
ENTEREVR PG SHIFTER ADJUSTMENT MODE
" in ELECTRICAL
ADJUSTMENT procedures.
Fig. 4-2
3. Press and hold STOP, PLAY, and VOL DOWN buttons on the unit
together over 5 seconds again or press the POWER button OFF to
release EVR Adjustment Mode.
The Default value will be written to Memory IC (IC6004).
4. Perform all EVR Adjustments. (Refer to "
EVR (Electronic Variable
Register) ADJUSTMENT WITH THE REMOTE CONTROL
" in
ELECTRICAL ADJUSTMENT procedures.)
13