Fig. M2-1
3. If the reading is out of specification, make sure that there is no
dust or foreign material between the Brake Pad of Tension Control
Arm Unit and the S Reel Table.
After cleaning, the reading of tension measurement is still out of
specification, replace the Tension Arm Unit and the Tension
Control Arm Unit.
Fig. M2-2
Note:
A. Be sure that the three probes of the meter are all in solid
contact with the tape, but not touching any other parts of the
mechanism.
B. It is recommended that measurements should be repeated at
least three (3) times because the tension meter is very sensitive
to external vibrations.
7.2.2.2. MR HEAD GAP ADJUSTMENT
Purpose:
To properly pick up the FG Signal.
Symptom of Misadjustment:
If the FG Signal is not properly picked up, Servo Operation cannot
49