Equipment:
Oscilloscope, MTS/SAP Signal Generator
1. Connect the RF OUTPUT of the MTS/SAP Signal Generator to the
Antenna Input Terminal.
2. Connect the Oscilloscope to TP9001 on the Audio C.B.A.
3. Set to TV mode, and then set to STEREO audio.
4. Adjust R9003 on the Audio C.B.A. so that the signal level is
minimum.
Fig. E3-1
5. Connect the Oscilloscope to TP9101 on the Audio C.B.A.
6. Adjust R9103 on the Audio C.B.A. so that the signal level is
minimum.
Fig. E3-2
7.3.5. FM VCO ADJUSTMENT
Purpose:
To set VCO free run frequency.
Symptom of Misadjustment:
Even when stereophony is received, only monaural sound will be
output.
60