background image

15

Screen 2

Screen 3

Screen 4

* For detailed configuration and management methods, and the 

settings from the ZEQUO assist Plus and the Web screens, please 

see the PDF version of the Operating Instructions on Panasonic’s 

website.

Summary of Contents for PN25168-NZ

Page 1: ... Switch by customers are not covered by the warranty I0217 50822 Printed in Japan GA AS16TPoE PN25168 TH PN25168 MY PN25168 ID PN25168 SG PN25168 NZ Model No The instruction manuals Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ew pewnw english datadownload index html 2 12 7 Higashi Shimbashi Minato ku Tokyo Japan 1...

Page 2: ...uct 1 Product Outline 1 1 Feature 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 3 Installation and Configuration 3 1 Grounding Cable Connection 3 2 Mounting to rack 3 3 Configuration of IP address Basic Troubleshooting 3 6 7 7 8 9 9 10 12 12 13 14 16 ...

Page 3: ...fire electric shock and or equipment failure Do not connect equipments other than 10BASE T 100BASE TX 1000BASE T to twisted pair port When connecting to a 10BASE T device use a Cat5 or above cable Deviation could lead to fire electric shock and or equipment failure Do not place this Ethernet Switch in harsh environment such as near water high humid and or high dust Deviation could lead to fire ele...

Page 4: ...ould lead to electric fire shock and or malfunction If the STATUS Status LED blinks orange unplug the power cord since this is a malfunction Deviation such as keep connecting for a long time could lead to fire Handle the Ethernet Switch carefully so that fingers or hands may not be damaged by twisted pair port or power cord hook block When connecting IEEE802 3at enabled receiving equipment to the ...

Page 5: ...power lines and communication lines Isolate distribution lines and other distribution lines and low current power lines optical fiber cables metallic water conduits and gas conduits etc Noise may be generated in the communication lines which might cause communication glitches CAUTION Important Requests on Protection from Lightning Strike If you connect a network camera a wireless access point or o...

Page 6: ...perature exceeding the specifications environment Strong vibration and or strong shock Please use this Ethernet Switch in place where ambient temperature is from 0 to 40 C If the supply power for the entire device is going to be used at 80 W or less use it in an area where it is 0 to 50 C Failure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfuncti...

Page 7: ...LPI compatible Energy Efficient Ethernet functions hereinafter EEE and if data is transmitted when linked up the energy efficient state will be moved to whereas each port can suppress power consumption Automatically detects the connection states via the equipped energy efficiency mode and suppresses power consumption to required levels VLAN function allows free grouping of up to 256 VLANs The IEEE...

Page 8: ...power supply 30 W per port 112 W in total Power supply method Altervative A Using idle line 1 2 3 6 Others Port Monitoring Storm control Power supply AC 100 240V 50 60 Hz 2 0 A Power consumption Normally Max 141 W 15 8 W when not supplying power Min 8 0 W Storage environment Temperature 20 70 C Humidity 10 90 RH no condensation Fan Installed Mass Weight 2 800 g External dimensions 44 mm Height 330...

Page 9: ...s LED lights up orange and the hardware runs a self diagnostic When it is finished both the the POWER power LED and STATUS status LED light up green and it operates as a Ethernet Switch As this Ethernet Switch succeeds in communicating with a terminal connected to each port LED of the port lights up When the terminal is not operating normally for example when power is not supplied to the terminal ...

Page 10: ... ground terminal screw 10BASE T 100BASE TX 1000BASE T port ports 1 18 Connect 10BASE T 100BASE TX 1000BASE T terminals hubs repeaters bridges and Ethernet Switches Install the device so that the length of the twisted pair cables CAT5e or above will be 100 m or less PoE power supply ports ports 1 16 The port can supply PoE power conforming with IEEE802 3at Connect a Powered Device conforming with I...

Page 11: ... limit LED Off Supplies power in a range of 0 105 W Green Light Supplies power in a range of 105 W 112 W Green Blink When the requested power supply capacity exceeds 112 W overload of the device overall Port LED Left LINK ACT ports 1 18 LED Green Light Link is established Green Blink Data is being sent received Off No terminal is connected Port LED Right PoE ports 1 16 LED Green Light Power is sup...

Page 12: ...ounding cable must be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed while normal operating servicing or maintenance 5 Installation steps Step 1 Ensure the detachable ...

Page 13: ... the mount brackets to the four holes on each side of the Ethernet Switch Then securely install the Ethernet Switch onto the rack using the four screws for a 19 inch rack mount supplied with the mount brackets or the screws supplied with the rack Right side Left side Screw holes for fixing the 19 inch rack mount brackets Installation on a rack 19 inch rack mount brackets Front ...

Page 14: ...thin the broadcast domain In a few seconds the screen displays the list of detected Ethernet Switches Screen 2 4 From the list of the detected Ethernet Switches select a device that you want to configure In the Setting item field in the lower part of the screen configure Network setting Switch name and other items 5 Fill in the setting items and press the Setting execution button to display the co...

Page 15: ... Screen 3 Screen 4 For detailed configuration and management methods and the settings from the ZEQUO assist Plus and the Web screens please see the PDF version of the Operating Instructions on Panasonic s website ...

Page 16: ...SE T 100BASE TX or 1000BASE T compatible Auto negotiation may be failing Set this device s port setting or the terminal s setting to half duplex Communication is slow Are the communication speed and mode settings correct If the proper communication mode signal cannot be obtained apply half duplex mode Please reconfirm Auto negotiation setting Is not the utilization ratio of the network to which th...

Page 17: ...ED is blinking in green Ensure that the total power supply demand from PoE powered devices does not exceed 112 W or 80 W If the supply power for the entire device is going to be used at 112 W or less use it in an area where it is 0 to 40 C If the supply power for the entire device is going to be used at 80 W or less use it in an area where it is 0 to 50 C When the power supply is suddenly shut off...

Reviews: