213
Screen Description
Global Loop
Detection Status
Shows the status of loop detection/shut-off function.
Enabled
The loop detection/shut-off function is enabled.
(Factory default setting)
Disabled
The loop detection/shut-off function is disabled.
Port
Shows the port number.
Trunk
Shows the link aggregation group ID.
Link
Shows the state of linkup.
Up
Link is up.
Down
Link is down.
State
Shows the behavior of loop detection/shut-off function.
Forwarding
Packet is normally forwarded.
Loop Detect Loop is detected and the port is shut off.
Loop Detect
Shows the status of loop detection/shut-off function of each port.
Enabled
The loop detection/shut-off function is enabled.
(Factory default setting: Port 1 to 14)
Disabled
The loop detection/shut-off function is disabled.
(Factory default setting: Port 15 to 16)
Recovery
Shows the recovery mode for auto-recovery of the shutoff port.
Enabled
Automatically recovers from port shutoff after the
recovery time elapses.
(Factory default setting)
Disabled
Does not recover from port shutoff until manually set.
Recovery Time
Shows the number of seconds for recovery time, which is standby time
until the shutoff port is automatically recovered. (Factory default
setting: 60)