179
Login failed from telnet
<IP: xxx.xxx.xxx.xxx>
Indicates a login authentication failure from the host with IP address
xxx.xxx.xxx.xxx via Telnet.
Login failed from SSH <IP:
xxx.xxx.xxx.xxx>
Indicates a login authentication failure from the host with IP address
xxx.xxx.xxx.xxx via SSH.
Reboot: Normal
Indicates that this Switching Hub was rebooted.
Reboot: Factory Default
Indicates that this Switching Hub was rebooted to return settings to
factory default.
Reboot: Factory Default
Except IP
Indicates that this Switching Hub was rebooted to return settings
except the IP address to factory default.
Reboot: Exception..
Indicates that this Switching Hub was rebooted due to exception han
-
dling.
Configuration changed
Indicates that the configuration was changed.
Switch start
Indicates that this Switching Hub was booted.
Runtime changes from
xxx.xxx.xxx.xxx
Indicates that firmware was downloaded from IP xxx.xxx.xxx.xxx and
updated.
Configuration file
uploaded
Indicates that the configuration file was uploaded via TFTP.
Configuration file down
-
loaded
Indicates that the configuration file was downloaded via TFTP.
Port-xx link-down
Indicates that Port xx was linked down.
Port-xx link-up
Indicates that Port xx was linked up.
Enter Command Line Inter
-
face
Indicates that the user moved from the configuration menu to CLI
(Command Line Interface).
xx:xx:xx:xx:xx:xx was
authorized at port xx.
Indicates that IEEE802.1X authentication succeeded on Port xx from
the terminal with xx:xx:xx:xx:xx:xx .
xx:xx:xx:xx:xx:xx was
rejected at port xx.
Indicates that IEEE802.1X authentication failed on Port xx from the ter
-
minal with xx:xx:xx:xx:xx:xx .
Authentication failure
Indicates that an unauthorized manager accessed by SNMP.
Port-xx Power ON notifica
-
tion
Indicates that the PoE power supply to Port xx is turned on.
Port-xx Power OFF notifica
-
tion
Indicates that the PoE power supply to Port xx is turned off.
SNTP first update to yyyy/
mm/dd
Indicates that the time was retrieved via SNTP for the first time.
FAN status changed from
good to failed
Indicates that a fan problem occurred.
FAN status changed from
failed to good.
Indicates that the internal fan recovered.
Sensor access error
Indicates that the internal sensor cannot be accessed.
(Bridge) Topology Change
Indicates that a topology change occurred in the Spanning Tree func
-
tion.
PortX auto recovery.
Indicates that Port X automatically recovered from being blocked after
loop detection.
The loop detected
between portA and portB.
Indicates that a loop was detected between Port A and Port B.
The loop detected on
portX.
Indicates that a loop was detected in Port X.
(RRP) FDB Flush
Indicates that Forwarding Database was flushed.
(RRP) Ring Recover
Indicates that a ring topology was restored.
This log is displayed for the Master nodes only.
(RRP) Ring Failure
Indicates that a ring topology problem occurred.
This log is displayed for the Master nodes only.