133
Screen Description
Admin
Displays whether or not power supply is possible.
The factory default setting is "Up."
Up
Power supply is possible.
Down
Power supply is not possible.
Sche.
Displays the PoE scheduler function status.
ON
Indicates that the power supply to the PoE is turned on by the PoE
scheduler.
OFF
Indicates that the power supply to the PoE is turned off by the PoE
scheduler.
-
Indicates that the PoE scheduler is not operating.
Status
Displays the power supply status.
Pwr
Power is supplied.
NotPwr
Power is not supplied.
Over
Power supply is stopped because the power request exceeds the
limit.
Layer
Displays the classification methods supported by the terminal device.
1
Power is supplied based on Physical Layer Classification.
2
Power is supplied based on Data Link Layer Classification.
Class
Displays the class selected by the Classification function.
Prio.
Displays the priority of power supply.
Crit.
Indicates the highest priority.
High
Indicates the second highest priority.
Low
Indicates no priority.
Limit
Displays the upper limit of power supply amount. (in units of 200 mW)
"Auto" is the factory default setting.
Pow.
Displays the amount of power supply. (in units of 100 mW)
Vol.
Displays the voltage. (in units of 1 V)
Cur.
Displays the current. (in units of 1 mA)