Performance Characteristic Tables
3
3.1.4 Capacity table PAW-VP1000LDHW (18 °C)
City water inlet temp:
18 °C
Outdoor unit type:
U-250PE2E8A
Tank type:
PAW-VP1000LDHW
Ambient
temperature
Water temp
Time
Heating
Capacity
Power Input
COP
WB
Set temp
[h:m:s]
[kWh]
[kWh]
+25°C
45°C
2:26:11
29.59
9.72
3.04
50°C
3:10:08
35.67
12.64
2.82
55°C
3:56:12
39.71
15.71
2.53
+20°C
45°C
2:31:04
29.59
10.05
2.95
50°C
3:16:28
35.67
13.07
2.73
55°C
4:04:05
39.71
16.23
2.45
+15°C
45°C
2:22:06
29.59
9.45
3.13
50°C
3:04:49
35.67
12.29
2.90
55°C
3:49:36
39.71
15.27
2.60
+12°C
45°C
2:25:02
29.59
9.64
3.07
50°C
3:08:37
35.67
12.54
2.84
55°C
3:54:20
39.71
15.58
2.55
+7°C
45°C
2:22:06
29.59
9.45
3.13
50°C
3:04:49
35.67
12.29
2.90
55°C
3:49:36
39.71
15.27
2.60
+2°C
45°C
2:46:38
29.59
11.08
2.67
50°C
3:36:44
35.67
14.41
2.47
55°C
4:29:15
39.71
17.91
2.22
+0°C
45°C
2:48:14
29.59
11.19
2.65
50°C
3:38:48
35.67
14.55
2.45
55°C
4:31:49
39.71
18.08
2.20
-2°C
45°C
2:47:22
29.59
11.13
2.66
50°C
3:37:41
35.67
14.48
2.46
55°C
4:30:26
39.71
17.98
2.21
-7°C
45°C
0:02:50
29.59
11.36
2.61
50°C
3:42:05
35.67
14.77
2.42
55°C
4:35:54
39.71
18.35
2.16
-10°C
45°C
2:53:35
29.59
11.55
2.56
50°C
3:45:46
35.67
15.01
2.38
55°C
4:40:29
39.71
18.65
2.13
-15°C
45°C
2:58:19
29.59
11.86
2.50
50°C
3:51:55
35.67
15.42
2.31
55°C
4:48:07
39.71
19.16
2.07
-20°C
45°C
3:03:03
29.59
12.17
2.43
50°C
3:58:04
35.67
15.83
2.25
55°C
4:55:46
39.71
19.67
2.02
• Based on peak cut setting 70%
• Please note: The data mentioned in this document is obtained by calculation.
Please use only for reference.
• Equivalent tubing length: 7.5 m, Difference of elevation: 0 m