39
PAW-VP•LDHW - Technical Manual – 2020-07
Performance Characteristic Tables
3
3.3 Capacity tables PAW-VP750LDHW
3.3.1 Capacity table PAW-VP750LDHW (10 °C)
City water inlet temp:
10 °C
Outdoor unit type:
U-250PE2E8A
Tank type:
PAW-VP750LDHW
Ambient
temperature
Water temp
Time
Heating Capacity Power Input
COP
WB
Set temp
[h:m:s]
[kWh]
[kWh]
+25°C
45°C
2:37:15
29.69
10.46
2.84
50°C
3:18:30
34.40
13.20
2.61
55°C
4:01:45
37.53
16.08
2.33
+20°C
45°C
2:42:29
29.69
10.81
2.75
50°C
3:25:07
34.40
13.64
2.52
55°C
4:09:49
37.53
16.61
2.26
+15°C
45°C
2:32:51
29.69
10.16
2.92
50°C
3:12:57
34.40
12.83
2.68
55°C
3:55:00
37.53
15.63
2.40
+12°C
45°C
2:26:00
29.69
10.37
2.86
50°C
3:16:55
34.40
13.10
2.63
55°C
3:59:50
37.53
15.95
2.35
+7°C
45°C
2:32:51
29.69
10.16
2.92
50°C
3:12:57
34.40
12.83
2.68
55°C
3:55:00
37.53
1.63
2.40
+2°C
45°C
2:59:15
29.69
11.92
2.49
50°C
3:46:16
34.40
15.05
2.90
55°C
4:35:35
37.53
18.33
2.05
+0°C
45°C
3:00:57
29.69
12.03
2.47
50°C
3:48:25
34.40
15.19
2.26
55°C
4:38:12
37.53
18.50
2.03
-2°C
45°C
3:00:02
29.69
11.97
2.48
50°C
3:47:16
34.40
15.11
2.28
55°C
4:36:47
37.53
18.41
2.04
-7°C
45°C
3:03:40
29.69
12.21
2.43
50°C
3:51:51
34.40
15.42
2.23
55°C
4:42:24
37.53
18.78
2.00
-10°C
45°C
3:06:43
29.69
12.42
2.39
50°C
3:55:42
34.40
15.67
2.19
55°C
4:47:04
37.53
19.09
1.97
-15°C
45°C
3:11:49
29.69
12.76
2.33
50°C
4:02:08
34.40
16.40
2.14
55°C
4:54:53
37.53
19.61
1.91
-20°C
45°C
3:16:54
29.69
13.09
2.27
50°C
4:08:33
34.40
16.53
2.08
55°C
37.53
20.13
1.86
• Based on peak cut setting 70%
• Please note: The data mentioned in this document is obtained by calculation.
Please use only for reference.
• Equivalent tubing length: 7,5 m, Difference of elevation: 0 m