41
PAW-VP•LDHW - Technical Manual – 2020-07
Performance Characteristic Tables
3
3.3.3 Capacity table PAW-VP750LDHW (15 °C)
City water inlet temp:
15 °C
Outdoor unit type:
U-250PE2E8A
Tank type:
PAW-VP750LDHW
Ambient
temperature
Water temp
Time
Heating Capacity Power Input
COP
WB
Set temp
[h:m:s]
[kWh]
[kWh]
+25°C
45°C
2:23:05
25.46
9.51
2.68
50°C
3:04:20
30.17
12.26
2.46
55°C
3:47:35
33.30
15.13
2.20
+20°C
45°C
2:27:51
25.46
9.83
2.59
50°C
3:10:29
30.17
12.67
2.38
55°C
3:55:10
33.30
15.64
2.13
+15°C
45°C
2:19:05
25.46
9.25
2.75
50°C
2:59:11
30.17
11.92
2.53
55°C
3:41:14
33.30
14.71
2.26
+12°C
45°C
2:21:57
25.46
9.44
2.70
50°C
3:02:52
30.17
12.16
2.48
55°C
3:45:47
33.30
15.01
2.22
+7°C
45°C
2:19:05
25.46
9.25
2.75
50°C
2:59:11
30.17
11.92
2.53
55°C
3:41:14
33.30
14.71
2.26
+2°C
45°C
2:43:06
25.46
10.85
2.35
50°C
3:30:08
30.17
13.97
2.16
55°C
4:19:26
33.30
17.25
1.93
+0°C
45°C
2:44:39
25.46
1.95
2.33
50°C
3:32:07
30.17
14.11
2.14
55°C
4:21:54
33.30
17.42
1.91
-2°C
45°C
2:43:49
25.46
10.89
2.34
50°C
3:31:03
30.17
14.03
2.15
55°C
4:20:34
33.30
17.33
1.92
-7°C
45°C
2:47:08
25.46
11.11
2.29
50°C
3:35:19
30.17
14.32
2.11
55°C
4:25:50
33.30
17.68
1.88
-10°C
45°C
2:49:54
25.46
11.30
2.25
50°C
3:38:53
30.17
14.56
2.07
55°C
4:30:15
33.30
17.97
1.85
-15°C
45°C
2:54:32
25.46
11.61
2.19
50°C
0:03:45
30.17
14.95
2.02
55°C
4:37:37
33.30
18.46
1.80
-20°C
45°C
2:59:10
25.46
11.91
2.14
50°C
3:50:49
30.17
15.35
1.97
55°C
4:44:58
33.30
18.95
1.76
• Based on peak cut setting 70%
• Please note: The data mentioned in this document is obtained by calculation.
Please use only for reference.
• Equivalent tubing length: 7,5 m, Difference of elevation: 0 m