40
PAW-VP•LDHW - Technical Manual – 2020-07
Performance Characteristic Tables
3
3.3.2 Capacity table PAW-VP750LDHW (12 °C)
City water inlet temp:
12 °C
Outdoor unit type:
U-250PE2E8A
Tank type:
PAW-VP750LDHW
Ambient
temperature
Water temp
Time
Heating Capacity Power Input
COP
WB
Set temp
[h:m:s]
[kWh]
[kWh]
+25°C
45°C
2:30:43
28.00
10.02
2.79
50°C
3:11:58
32.71
12.77
2.56
55°C
3:55:13
35.84
15.64
2.29
+20°C
45°C
2:35:44
28.00
10.36
2.70
50°C
3:18:22
32.71
13.19
2.48
55°C
4:03:04
35.84
16.16
2.22
+15°C
45°C
2:35:44
28.00
10.36
2.70
50°C
3:18:22
32.71
13.19
2.48
55°C
4:03:04
35.84
16.16
2.22
+12°C
45°C
2:29:31
28.00
9.94
2.82
50°C
3:10:27
32.71
12.66
2.58
55°C
3:53:21
35.84
15.52
2.31
+7°C
45°C
2:26:30
28.00
9.74
2.87
50°C
3:06:36
32.71
12.41
2.64
55°C
3:48:39
35.84
15.20
2.36
+2°C
45°C
2:51:48
28.00
11.42
2.45
50°C
3:38:49
32.71
14.55
2.25
55°C
4:28:08
35.84
17.83
2.01
+0°C
45°C
2:53:26
28.00
11.53
2.43
50°C
3:40:54
32.71
14.69
2.23
55°C
4:30:41
35.84
18.00
1.99
-2°C
45°C
2:52:33
28.00
11.47
2.44
50°C
3:39:47
32.71
14.62
2.24
55°C
4:29:18
35.84
17.91
2.00
-7°C
45°C
2:56:02
28.00
11.71
2.39
50°C
3:44:13
32.71
14.91
2.19
55°C
4:34:45
35.84
18.27
1.96
-10°C
45°C
2:58:58
28.00
11.90
2.35
50°C
3:47:57
32.71
15.16
2.16
55°C
4:39:19
35.84
18.57
1.93
-15°C
45°C
3:03:50
28.00
12.23
2.29
50°C
3:54:10
32.71
15.57
2.10
55°C
4:46:55
35.84
19.08
1.88
-20°C
45°C
3:08:43
28.00
12.55
2.23
50°C
4:00:22
32,71
15,98
2,05
55°C
4:54:32
35,84
19,59
1,83
• Based on peak cut setting 70%
• Please note: The data mentioned in this document is obtained by calculation.
Please use only for reference.
• Equivalent tubing length: 7,5 m, Difference of elevation: 0 m