3
3.3.4 Capacity table PAW-VP750LDHW (18 °C)
City water inlet temp:
18 °C
Outdoor unit type:
U-250PE2E8A
Tank type:
PAW-VP750LDHW
Ambient
temperature
Water temp
Time
Heating
Capacity
Power Input
COP
WB
Set temp
[h:m:s]
[kWh]
[kWh]
+25°C
45°C
2:18:45
22.96
9.23
2.49
50°C
3:00:00
27.67
11.97
2.31
55°C
3:43:15
30.81
14.85
2.08
+20°C
45°C
2:23:23
22.96
9.53
2.41
50°C
3:06:00
27.67
12.37
2.24
55°C
3:50:42
30.81
15.34
2.01
+15°C
45°C
2:14:53
22.96
8.97
2.56
50°C
2:54:59
27.67
11.64
2.38
55°C
3:37:01
30.81
14.43
2.13
+12°C
45°C
2:17:39
22.96
9.15
2.51
50°C
2:58:35
27.67
11.88
2.33
55°C
3:41:29
30.81
14.73
2.09
+7°C
45°C
2:14:53
22.96
8.97
2.56
50°C
2:54:59
27.67
11.64
2.38
55°C
3:37:01
30.81
14.43
2.13
+2°C
45°C
2:38:10
22.96
10.52
2.08
50°C
3:25:12
27.67
13.65
2.03
55°C
4:14:30
30.81
16.92
1.82
+0°C
45°C
2:39:40
22.96
10.62
2.16
50°C
3:27:09
27.67
13.78
2.01
55°C
4:16:55
30.81
17.09
1.80
-2°C
45°C
2:38:52
22.96
10.56
2.17
50°C
3:26:05
27.67
13.70
2.02
55°C
4:15:36
30.81
17.00
1.81
-7°C
45°C
2:42:04
22.96
10.78
2.13
50°C
3:30:15
27.67
13.98
1.98
55°C
4:20:47
30.81
17.34
1.78
-10°C
45°C
2:44:46
22.96
10.96
2.01
50°C
3:33:45
27.67
14.21
1.95
55°C
4:25:07
30.81
17.63
1.75
-15°C
45°C
2:49:15
22.96
11.26
2.04
50°C
3:39:34
27.67
14.60
1.90
55°C
4:32:20
30.81
18.11
1.70
-20°C
45°C
2:53:44
22.96
11.55
1.99
50°C
3:45:24
27.67
14.99
1.85
55°C
4:29:33
30.81
1.86
1.66
• Based on peak cut setting 70%
• Please note: The data mentioned in this document is obtained by calculation.
Please use only for reference.
• Equivalent tubing length: 7,5 m, Difference of elevation: 0 m