45
PAW-VP•LDHW - Technical Manual – 2020-07
Performance Characteristic Tables
3
3.5 Cooling capacity table PAW-VP380L
Operation type:
Cooling capacity
Outdoor unit type:
U-200PZH2E8
Tank type:
PAW-VP380L
Ambient
temperature
Δt 5K
Cooling capacity
Power Input
EER
Water Outlet
[kW]
[kW]
[kW/kW]
+40°C
5°C
10.20
7.75
1.32
7°C
11.69
8.93
1.31
12°C
20.40
9.44
2.16
+35°C
5°C
11.20
6.74
1.66
7°C
12.80
8.00
1.60
15°C
22.40
8.43
2.66
+30°C
5°C
12.00
5.90
2.03
7°C
13.75
7.10
1.94
12°C
22.80
7.70
2.96
+25°C
5°C
12.54
5.05
2.48
7°C
14.37
5.98
2.40
12°C
23.00
6.30
3.65
+20°C
5°C
13.21
4.88
2.71
7°C
15.14
5.73
2.64
12°C
23.40
6.11
3.83
+15°C
5°C
12.15
4.80
2.53
12°C
13.92
5.64
2.47
15°C
23.30
6.11
3.81
+10°C
5°C
12.32
4.72
2.61
7°C
14.11
5.56
2.54
12°C
23.20
5.81
3.99
+2°C
5°C
12.54
4.63
2.71
7°C
14.24
5.47
2.60
12°C
23.00
5.73
4.01
0°C
5°C
12.54
4.55
2.76
7°C
14.37
5.39
2.67
12°C
22.90
5.64
4.06
-7°C
5°C
11.42
4.38
2.61
7°C
13.90
5.22
2.66
12°C
22.84
5.56
4.11
-10°C
5°C
11.48
4.29
2.68
7°C
13.15
5.14
2.56
12°C
22.90
5.39
4.25
Please note: The data mentioned in this document is obtained by calculation.
Please use only for reference.