19/51
2.51. DISPLAY DOTS
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 44h 44h 3Ah
Character
A D Z Z ; V D D :
Hexadecimal *1 *3 *5 *7 03h
Character
*2 *4 *6 *8
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
300
301
Hexadecimal
30h 33h 30h 30h 30h 33h 30h 31h
Character 0 3 0 0 0 3 0 1
4065
4066
Hexadecimal
34h 30h 36h 35h 34h 30h 36h 36h
Character 4 0 6 5 4 0 6 6
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h 56h 44h 44h 3Ah *1 *3 *5 *7 03h
Character
V D D : *2 *4 *6 *8
Acceptability
SECURITY STNDBY NO
SIGNAL SHUTTER FREEZE TEST
PATTERN REMOTE2
No
No
No
Yes
No Yes Yes
VIDEO S-VIDEO RGB1
RGB2 YP
B
P
R
1 YP
B
P
R
2 DVI
No No Yes Yes No
No
No
Note:
• The maximum value that can be actually set changes according to the input signal or the input resolution settings, etc.
• Calls back ER402 when the value of more than number in which 30 is subtracted from number of total dots is specified.
2.52. TOTAL LINES
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 54h 4Ch 3Ah
Character
A
D
Z
Z
;
V
T
L
:
Hexadecimal *1 *3 *5 *7 03h
Character
*2 *4 *6 *8
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
306
307
Hexadecimal
30h 33h 30h 36h 30h 33h 30h 37h
Character 0 3 0 6 0 3 0 7
2046
2047
Hexadecimal
24h 30h 34h 36h 32h 30h 34h 37h
Character 2 0 4 6 2 0 4 7
Response (Callback)
In the period when the command can be accepted
Hexadecimal
02h 56h 54h 4Ch 3Ah *1 *3 *5 *7 03h
Character V T L : *2 *4 *6 *8
Acceptability
SECURITY STNDBY NO
SIGNAL SHUTTER FREEZE TEST
PATTERN REMOTE2
No
No
No
Yes
No Yes Yes
VIDEO S-VIDEO RGB1
RGB2 YP
B
P
R
1 YP
B
P
R
2 DVI
No No Yes Yes No
No
No
Note:
• The maximum value that can be actually set changes according to the input signal or the input resolution settings, etc.
• Calls back ER402 when the value of less than number in which 6 is added to number of display lines is specified.