Chapter 4
Settings — [PROJECTOR SETUP] menu
112 - ENGLISH
Setting [BRIGHTNESS CONTROL SETUP]
Set brightness control operation.
1) Press
as
to select [BRIGHTNESS CONTROL].
2) Press the <ENTER> button.
f
The
[BRIGHTNESS CONTROL]
screen is displayed.
3) Press
as
to select [BRIGHTNESS CONTROL SETUP].
4) Press the <ENTER> button.
f
The
[BRIGHTNESS CONTROL SETUP]
screen is displayed.
5) Press
as
to select [MODE].
6) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Does not correct the brightness of the screen by the brightness sensor.
[AUTO]
Corrects the brightness of the screen by the brightness sensor.
Automatically corrects screen brightness when lamp brightness changes.
[PC]
Synchronizes nine or more projectors through a computer using the dedicated software “Multi
Projector Monitoring & Control Software”
*1
.
*1
“Multi Projector Monitoring & Control Software” is included in the supplied CD-ROM.
f
When [AUTO] is selected, proceed to Step
7)
.
7) Press
as
to select [LINK].
8) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Performs corrections by the brightness sensor in one projector without synchronizing with the other
projectors.
The period, in which the constant brightness kept by the small value of [BRIGHTNESS CONTROL
GAIN], is prolonged.
[GROUP A]
[GROUP B]
[GROUP C]
[GROUP D]
Synchronizes corrections in multiple projectors by the brightness sensor.
You can set up to four groups (A to D) within the same subnet by using the network function.
You can also register and synchronize up to eight projectors in one group.
9) Press
as
to select [CALIBRATION TIME].
10) Press the <ENTER> button.
f
Enters adjustment mode (the display is blinking).
11) Press
qw
to select “hour” or “minute”, and press
as
or the number (<0> - <9>) buttons to set a
time.
f
Selecting “hour” allows setting of only the hour in increments of one hour, and selecting “minute” allows setting of only the minute in
increments of one minute between 00 and 59.
f
If you do not specify the time, select [OFF] between 23 and 00 o’clock or between 59 and 00 minutes.
12) Press the <ENTER> button.
f
[CALIBRATION TIME] is set.
f
Measures the brightness at the specified time. Iris is fixed to open during measurement.
13) Press
as
to select [CALIBRATION MESSAGE].
14) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[ON]
Messages are displayed during calibration.
[OFF]
Messages are not displayed during calibration.
15) Press
as
to select [APPLY].