Chapter 6
Appendix — Technical information
158 - ENGLISH
Channel
Control details
Performance
Parameter
Remark
8
Fade-in time setting
0.0s
0-15
Operate together with channel 1.
0.5s
16-31
1.0s
32-47
1.5s
48-63
2.0s
64-79
2.5s
80-95
3.0s
96-111
3.5s
112-127
4.0s
128-143
5.0s
144-159
7.0s
160-175
10.0s
176-191
No operation
192-255
―
9
Fade-out time setting
0.0s
0-15
Operate together with channel 1.
0.5s
16-31
1.0s
32-47
1.5s
48-63
2.0s
64-79
2.5s
80-95
3.0s
96-111
3.5s
112-127
4.0s
128-143
5.0s
144-159
7.0s
160-175
10.0s
176-191
No operation
192-255
―
10
No operation
―
―
―
11
Geometric adjustment
OFF
0-15
―
KEYSTONE
16-31
CURVED
32-47
No operation
48-95
CORNER CORRECTION
96-111
No operation
112-255
Note
f
If the projector is operated with the remote control or on the control panel, or by the control command while controlling the projector using
the Art-Net function, the setting of the DMX controller and the computer application may be different from the projector status. To reflect the
controls of all channels to the projector in that case, set “Lock” of channel 7 to “Operation not available” and then set back to “Operation
available”.
Control commands via LAN
When web control administrator rights password is set (Protect mode)
Connecting
1)
Obtain the IP address and port number (Initial set value = 1024) of the projector and request for a
connection to the projector.
f
You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Obtain from the main menu
→
[NETWORK]
→
[NETWORK STATUS]
Port number
Obtain from the main menu
→
[NETWORK]
→
[NETWORK CONTROL]
→
[COMMAND PORT]
2)
Check the response from the projector.