Chapter 4
Settings — [PROJECTOR SETUP] menu
174 - ENGLISH
Setting the communication condition of the <SERIAL OUT> terminal
1) Press
as
to select [RS-232C].
2) Press the <ENTER> button.
f
The
[RS-232C]
screen is displayed.
3) Press
as
to select [(OUT) BAUDRATE].
4) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[9600]
Select the proper speed.
[19200]
[38400]
5) Press
as
to select [(OUT) PARITY].
6) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[NONE]
Select the parity condition.
[EVEN]
[ODD]
Setting the response
1) Press
as
to select [RS-232C].
2) Press the <ENTER> button.
f
The
[RS-232C]
screen is displayed.
3) Press
as
to select [RESPONSE(ID ALL)].
4) Press
qw
to switch the item.
[ON]
Returns the response when an ID is designated as ALL.
[OFF]
Does not return the response when an ID is designated as ALL.
5) Press
as
to select [GROUP].
6) Press
qw
to switch the item.
[A] - [Z]
Controls multiple projectors simultaneously by sending the ID of RS-232C. You can set groups from
[A] to [Z]. The projector responds when the ID of RS-232C matches the setting.
7) Press
as
to select [RESPONSE(ID GROUP)].
8) Press
qw
to switch the item.
[ON]
Returns the response when an ID is designated as GROUP.
[OFF]
Does not return the response when an ID is designated as GROUP.
Note
f
When [INPUT SELECT] is set to [DIGITAL LINK], communication using the serial terminal is available only when the corresponding device
(such as the optional DIGITAL LINK output supported device (Model No.: ET-YFB100G, ET-YFB200G) connected to the <DIGITAL LINK IN/
LAN> terminal of the optional DIGITAL LINK Terminal Board (Model No.: TY-SB01DL) installed in the slot) is connected.
f
When [INPUT SELECT] is set to [DIGITAL LINK], communication speed for input is fixed to 9 600 bps and the parity is fixed to “NONE”.
[REMOTE2 MODE]
You can set the <REMOTE 2 IN> terminal.
1) Press
as