Chapter 4
Settings — [PROJECTOR SETUP] menu
128 - ENGLISH
Setting [BRIGHTNESS CONTROL SETUP]
Set the operation of the brightness control function.
The [BRIGHTNESS CONTROL SETUP] setting is synchronized with the [PROJECTOR SETUP] menu
→
[BRIGHTNESS CONTROL]
→
[BRIGHTNESS CONTROL SETUP]. The most recent setting is reflected in both
items.
1) Press
as
to select [OPERATION SETTING].
2) Press the <ENTER> button.
f
The
[OPERATION SETTING]
screen is displayed.
3) Press
as
to select [CONSTANT MODE].
4) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Does not correct the brightness of the screen by the brightness sensor.
[AUTO]
Corrects the brightness of the screen by the brightness sensor.
When the brightness of light source or white balance changes, the brightness of the screen is
automatically corrected.
[PC]
Synchronizes nine or more projectors using a computer and the dedicated software “Multi Monitoring
& Control Software”
*1
.
*1
“Multi Monitoring & Control Software” is included in the supplied CD-ROM.
f
When [PC] is selected, proceed to Step
7)
.
5) Press
as
to select [LINK].
6) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Performs correction by the brightness sensor on one projector without synchronizing with the other
projectors.
The duration that the constant brightness is kept will become longer by setting the value of [LIGHT
OUTPUT] smaller.
[GROUP A]
[GROUP B]
[GROUP C]
[GROUP D]
Performs correction by the brightness sensor in multiple projectors in synchronization.
Up to four groups (A to D) can be set within the same subnet by using the network function.
You can register and synchronize up to eight projectors in one group.
7) Press
as
to select [CALIBRATION TIME].
8) Press the <ENTER> button.
f
The projector is in the adjustment mode (the time is blinking).
9) Press
qw
to select “hour” or “minute”, and press
as
or the number (<0> - <9>) button to set a time.
f
Selecting “hour” allows setting of only the hour in increments of one hour, and selecting “minute” allows
setting of only the minute in increments of one minute between 00 and 59.
f
When the time is not specified, select [OFF] between 23 and 00 of the hour, or between 59 and 00 of the
minute.
10) Press the <ENTER> button.
f
[CALIBRATION TIME] is set.
f
Brightness and color are measured at the specified time. The dynamic contrast function does not operate
during measurement.
11) Press
as
to select [CALIBRATION MESSAGE].
12) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[ON]
Displays the message during calibration.
[OFF]
Does not display the message during calibration.
13) Press
as
to select [APPLY].