Chapter 4
Settings — [SIGNAL LIST] menu
ENGLISH - 181
f
This function can be used when a signal is input from the <RGB 1 IN> terminal, the <RGB 2 IN> terminal, <DVI-D IN> terminal, the <HDMI
IN> terminal, or the <DIGITAL LINK/LAN> terminal.
f
When [WIDE] is set, the image may be distorted because a signal is recognized as the same even if its synchronizing frequency varies
slightly.
f
When a signal to be input corresponds to multiple signals set in [WIDE], a registered signal with a high memory number receives priority.
Example: a signal to be input that corresponds to memory numbers A2, A4 and B1 will be determined to be B1.
f
When a registration signal is deleted, the settings are also deleted.
f
In an environment where multiple types of signals are input to the same terminal, signals are sometimes not determined correctly when the
setting is set to [WIDE].
Sub memory
The projector has a sub memory function that can register the multiple image adjustment data, even if it is
recognized as the same signal by the frequency or format of the synchronization signal source.
Use this function when you need to switch the aspect or adjust the picture quality such as the white balance while
using the same signal source. The sub memory includes all the data that can be adjusted for each signal, such as
the screen aspect ratio and data adjusted in the [PICTURE] item (such as [CONTRAST], [BRIGHTNESS]).
Registering to the sub memory
1) While in the normal screen (where no menu is displayed), press
qw
.
f
The sub memory registration screen is displayed if the sub memory is not registered. Proceed to Step
3)
.
f
A list of sub memories registered to the signal currently input is displayed.
f
The <FUNCTION> button on the remote control can be used instead of the
qw
button when [SUB
MEMORY] is selected from the [PROJECTOR SETUP] menu
→
[FUNCTION BUTTON].
2) Press
asqw
to select the sub memory number to register in [SUB MEMORY LIST].
3) Press the <ENTER> button.
f
The
[SIGNAL NAME CHANGE]
screen is displayed.
4) Press
asqw
to select [OK], and press the <ENTER> button.
f
To rename the registered signal, follow the procedure in Steps
6)
and
7)
in “Renaming the registered signal”
(
x
page 179).
Switching to the sub memory
1) While in the normal screen (where no menu is displayed), press
qw
.
f
A list of sub memories registered to the signal currently input is displayed.
2) Press
asqw
to select the signal to switch in [SUB MEMORY LIST].
3) Press the <ENTER> button.
f
This switches to the signal selected in Step
2)
.
Deleting the sub memory
1) While in the normal screen (where no menu is displayed), press
qw
.
f
The
[SUB MEMORY LIST]
screen is displayed.
2) Press
asqw
to select the sub memory to be deleted, and press the <DEFAULT> button on the
remote control.
f
The
[REGISTERED SIGNAL DELETE]
screen is displayed.
f
To cancel the deletion, press the <MENU> button to return to the
[SUB MEMORY LIST]
screen.
3) Press the <ENTER> button.
f