INF - 17
6. 2. Shutdown system
When something wrong such as stop of fan happens, the projector has a function to be on standby immediately.
LD unit temperature sensor
⇒
Under -36 degrees
Connection problem with LD temperature sensor
Faulty temperature sensor
-
LED-R temperature sensor
⇒
Under -45 degrees
Connection problem with LED-R unit
-
LED-B temperature sensor
⇒
Under -45 degrees
Connection problem with LED-B unit
-
Intake air temperature sensor
⇒
Under -45 degrees
Connection problem with Intake air temperature
sensor
Faulty temperature sensor
-
DMD temperature sensor
⇒
Under -36 degrees
Connection problem with DMD temperature sensor
Faulty temperature sensor
-
Internal air temperature problem
Fresh air intake port is blocked up
DMD temperature is low.
Adjust the Installation environment.
Phosphor wheel fault
-
-
58 degrees
"TEMPERATURE WARNING"
56 degrees
warning cancel
All light source lighting failure
Driver circuit fault
Connection error
68 degrees
"TEMPERATURE WARNING"
66 degrees
warning cancel
-
DMD temperature error.
Fresh air intake port is blocked up
Failure of the heat sink mounting
46 degrees
"TEMPERATURE WARNING"
45 degrees
warning cancel
-
-
Abnormality of fan rotation
OSD warning
-
-
-
-
Possible factor
Blown out of the fuse
( with some reason )
Signal processing unit PCB is faulty
DMD drive circuit is faulty or
Signal processing unit PCB is faulty or
Connector connection is faulty
Top cover is not installed.
-
Abnormalities in fan connection
Fan failure
Connection problem with Internal air temperature
sensor
Faulty temperature sensor
-
LIGHT LED
blinks 2
times
Phosphor wheel Index signal
⇒
45 Hz or less
Monitor LED indication
Each FAN sense signal
is undetectable.
STANDBY/ON LED: Red
TEMP LED: Lights
No flashing or blinking
Each FAN sense signal
⇒
Less than 70% of target rotations
is 120 sec or more.
Power fuse
⇒
K-P.C.B : 10A 250V
⇒
P-P.C.B : 2A 250V
⇒
B-P.C.B : 5A 250V
FPGA initialized or
Communication error
Shutdown detection
Formatter initial error
Interlock switch
TEMP LED
Blinks 3 times
Internal air temperature sensor
⇒
Under -45 degrees
TEMP LED
Blinks 2
times
(Warning: TEMP LED
lights)
Internal air temperature sensor
⇒
More than 70 degrees
LIGHT LED
blinks 3
times
All the light source errors
⇒
Status signal from the driver
microcontroller, all light source is
other than during normal operation.
Intake air temperature sensor
⇒
More than 47 degrees
Intake air temperature problem
Fresh air intake port is blocked up
Outside air temperature is high.
LD unit temperature sensor
⇒
After light source lighting, less
than 0 degrees for more than 5 min.
LD unit temperature is low.
Adjust the Installation environment.
DMD temperature sensor
⇒
After light source lighting, less
than 5 degrees for more than 5 min.
DMD temperature sensor
⇒
More than 60 degrees
Summary of Contents for PT-RZ470 Series
Page 6: ...6 2 Specifications...
Page 7: ...7...
Page 9: ...INF 2 1 The name of each part 1 1 Projector body 1 2 Control panel...
Page 10: ...INF 3 1 3 Connecting terminals 1 4 Remote control...
Page 11: ...INF 4 2 OSD Menu Navigation...
Page 12: ...INF 5...
Page 13: ...INF 6...
Page 26: ...INF 19 5 Select Log SYSTEM and click Get button 6 Log is displayed...
Page 84: ......