ADJ - 8
1. 6. Drive Current, White balance, Color luminance adjustment
1. 6. 1. Necessary equipments
1. Dark room : To measure the light level/color points.
2. Screens : Appros 40 inch diagonal size white mat type screen.
3. Luminqance/Color meter : recommend Konica-Minolta CL-200.
4. Serial cable from Luminance/Color meter to PC : In case using CL-200, T-A11 is the type number.
5. PC : To make communication between Luminance/Color meter to the projector.
6. Serial cable : RS-232C streight with D-sub9 male/female type for communicationg between PC to projector.
7. Service tool software : SSI_Service_Tool
(
Please download from service web page)
1. 6. 2. Preparation
1. Set the projector lens at center position with wide end zoom.
2. Set the throw distance at 1.25
~
1.30m
(
approx 40inch
)
3. Connect serial cable between projector and PC.
4. Connect Serial cable (T-A11) between Luminance/Color meter
(
CL-200A
)
.
1. 6. 3. Start up the equipments
1. Power on the projector.
2. Start-up the service tool software "SSI_Service_Tool" on the PC.
3. Communicate automatically, when start the SSI_Service_Tool.
●
"Model Info" will be displayed if it succeeds in communication.
This process shows how to adjust each light source device (LED-R, LED-B, LD, Phosphor wheel
)
driving level.
Please follow these process when these devices are replaced.
Dark room
Serial cable (T-A11)
1.25
~
1.30m
Table
RS-232 straight
Luminance/Color meter
S
cr
een
PJ
PC
Summary of Contents for PT-RZ470 Series
Page 6: ...6 2 Specifications...
Page 7: ...7...
Page 9: ...INF 2 1 The name of each part 1 1 Projector body 1 2 Control panel...
Page 10: ...INF 3 1 3 Connecting terminals 1 4 Remote control...
Page 11: ...INF 4 2 OSD Menu Navigation...
Page 12: ...INF 5...
Page 13: ...INF 6...
Page 26: ...INF 19 5 Select Log SYSTEM and click Get button 6 Log is displayed...
Page 84: ......