118 - ENGLISH
The time which is displayed in [LAMP] is a total time when the real usage time in [NORMAL], [ECO] or [QUIET] is
converted to the runtime in [ECO]. Please note that they are not displayed individually.
The displayed time in [LAMP] =
“Lamp runtime of [NORMAL]” × 2 + “Lamp runtime of [ECO]” + “Lamp runtime of [QUIET]” × 2
The real usage time when the displayed time in [LAMP] is 20 000 hours means,
When [Lamp control] is constantly set to [NORMAL] without switching to other modes = 10 000 hours
When [Lamp control] is constantly set to [ECO] without switching to other modes = 20 000 hours
When [Lamp control] is constantly set to [QUIET] without switching to other modes = 10 000 hours
If you continue to use the lamp unit when the displayed time in [LAMP] has reached 20 000 hours, the lamp
turns off automatically at approximately 10 minutes after turning on the power, as it will cause malfunction of the
projector.
The displayed
time in [LAMP]
On-screen display
<WARNING> indicator
19 700 hours ~
20 000 hours
f
The lamp replacement warning message of “REPLACE
LAMP” is displayed for 30 seconds. If you press any button
within 30 seconds, the warning message disappears.
Off
Over 20 000 hours
f
The countdown warning message of “REPLACE LAMP
THE PROJECTOR WILL SHUT DOWN AFTER **
MINUTES.” (“**” indicates the countdown time) is displayed
for 10 minutes. The countdown warning message will
disappear if you press any button within 10 minutes and will
reappear on the screen after 1 minute.
f
The countdown warning message will be displayed on
the screen each time the input is switched or the projector
power is turned on.
f
The projector will power off automatically approximately 10
minutes after the lamp is turned on.
Blinking red (even in standby mode)
Note
f
The lamp replacement warning message will not be displayed in "Freeze" or "AV mute" status.
f
The usage period of 20 000 hours which is displayed in [PROJECTOR SETUP] menu → [STATUS] → [RUNTIME] → [LAMP] is a rough
estimate and is not guaranteed.
Replacing the Lamp unit
Attention
f
When the projector is mounted on a ceiling, do not work with your face close to the projector.
f
Do not remove or loosen the screws other than specified ones when replacing the lamp unit.
f
Make sure to attach the lamp unit and the lamp cover securely.
Lamp cover
Lamp cover
fixing screw
AC IN
Handles
Lamp
unit fixing
screws
1) Turn off the power by following the procedure in “Powering off the projector” (
x
page 39). Remove
the AC power plug from the wall outlet.
f
Wait at least 1 hour and make sure the lamp unit and surroundings are cool.
2) Use a Phillips screwdriver to loosen the lamp cover fixing screw (×1) until it turns freely and remove
the lamp cover.
f
Remove the lamp cover by pulling it slowly toward the direction of the arrow as the above figure shown.
3) Use a Phillips screwdriver to loosen the three lamp unit fixing screws (×3) until they turn freely.
Chapter 6 Maintenance - Maintenance/replacement