1 [PROJECTOR TYPE]
Displays the type of projector.
2 [PROJECTOR NAME]
Displays the name set in the projector.
3 [MAIN VERSION]
Displays the firmware version of the projector.
4 [POWER]
Displays the status of the power.
5 [PICTURE MODE]
Displays the status of the picture mode.
6 [SERIAL NUMBER]
Displays the serial number of the projector.
7 [NETWORK VERSION]
Displays the version of firmware of the network.
8 [AV MUTE]
Displays the AV mute status.
9 [VOLUME]
Displays the volume status.
10 [INPUT]
Displays the status of the selected input.
11 [INTAKE AIR TEMPERATURE]
Displays the status of the air intake temperature of the
projector.
12 [EXHAUST AIR TEMPERATURE]
Displays the status of the exhaust air temperature of the
projector.
13 [OPTIC MODULE TEMPERATURE]
Displays the optics module temperature status of the
projector.
14 [LAMP RUNTIME]
Displays the runtime of the lamp (converted value).
15 [SELF TEST]
Displays the self diagnostics information.
16 [PROJECTOR RUNTIME]
Displays the runtime of the projector.
Error information page
When [Error (Detail)] or [Warning (Detail)] is displayed in the self-diagnosis display of the [Projector status] screen, click it to
display the error/warning details.
f
The projector may go into the standby status to protect the projector depending on the contents of the error.
PT-VW355N
1 Self-diagnosis result display
Displays the item check results.
[OK]:
Indicates that operation is normal.
[FAILED]:
Indicates that there is a problem.
[WARNING]:
Indicates that there is a warning.
r
[FAILED] items displayed when a problem occurs
Parameter
Description
[FAN]
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
[FAN(INTAKE)]
Trouble has occurred in the intake fan.
[FAN(EXHAUST)]
Trouble has occurred in the exhaust fan.
[FAN(LAMP)]
Trouble has occurred in the lamp cooling fan.
[INTAKE AIR TEMPERATURE]
The air intake temperature is too high. The projector may be used in an operating
environment where the temperature is high, such as near a heating appliance.
[EXHAUST AIR TEMPERATURE]
The exhaust air temperature is high. The air exhaust port may be blocked.
[OPTICS MODULE TEMPERATURE]
The temperature around the optics module inside the projector is high. The projec
-
tor may be used in an operating environment where the temperature is high, such
as near a heating appliance.
102 -
ENGLISH
Chapter 4 Settings - [NETWORK/USB] menu
Chapter 4 Settings - [NETWORK/USB] menu