(17)-
Rotation check of Exhaust fan and Power fan (Displays "NG" when Fan is abnormal condition)
(18)-
Lens memory operation abnormality check (Abnormal condition = "NG")
(19)-
Judgment for Replacement Time of Lamp (Cumulative Usage more than 4000H is "NG")
* Warning of the lamp cumulative usage time and shutdown use the conversion time for LAMP POWER "NOMAL".
(20)-
The number of times that carried out reset of "LAMP RUNTIME"
(21)-
Cumulative usage time (conversion for LAMP POWER "NOMAL" time) and Number of LAMP ON times
"Current number : Last reset : Reset of last but one"
4.STATUS
・
Display version of each software and each data.
5.FLICKER ADJUST
・
To enter the flicker adjustment mode.
Note: If replacing the optical parts (Optical block) or A-P.C.Board, adjust to flicker is minimum according to the
"SECTION 3 Flicker adjustment".
* When detected abnormal temperature around the air intake port / air exhaust port / LCD block,
TEMP indicator turned on. If arriving at the critical temperature, the power supply will shut down
automatically (thermal shutdown) and the indicator will flash.
STATUS
MODEL TYPE
PT-AE8000U
SERIAL NUMBER
SA*******
DYNAMIC GAMMA
OK
UNIFORMITY
OK
-------- SOFT VERSION --------
MAIN
1.00
SUB
1.00
IRIS
1.02
FPGA
1.00
FRC ID MAJOR
04000000
FRC ID MINOR
07000000
FRC CONFIG MAJOR 01000000
FRC CONFIG MINOR 00000000
-------- DATA VERSION --------
BITMAP
1.00
ENG FONT
1.00
RUS FONT
1.00
THA FONT
1.00
KOR FONT
1.00
CHI FONT
1.00
JPN FONT
1.00
ET7140 GAMMA
1.00
COLOR MANAGEMENT 1.01
x.v.Color
1.00
OD
1.03
DETAIL CLARITY
1.00
INF - 7
Summary of Contents for PT_AT6000E
Page 8: ...1 Name and function 1 1 Projector body Top and front view Back and bottom view INF 2 ...
Page 9: ...1 2 Control Panel 1 3 Rear terminals 1 4 Remote control INF 3 ...
Page 11: ... MENU MENU 2 2 Note The default settings may be different depending on the picture menu INF 5 ...
Page 16: ...4 7 Inquiry commands Refer to Operating Instructions of PT AE8000 PT AT6000 INF 10 ...
Page 75: ......