[PICTURE] menu
ENGLISH
- 43
Settings
1) Adjust [FULL SCAN(Y)] / [SINGLE LINE
SCAN(Y)].
z
Set on [PICTURE] and use the
▲ ▼
buttons to
adjust [BRIGHTNESS] and then [CONTRAST].
[BRIGHTNESS]
Adjust the bottom line of the
waveform to 0 %
(0 or 7.5 IRE)
z
Setting range:
−32 to +32
[CONTRAST]
Adjust the top line of the
waveform to 100 %
(100 IRE)
z
Setting range:
−64 to +64
2) Adjust [FULL SCAN(R)] / [SINGLE LINE
SCAN(R)].
z
Set on [ADVANCED MENU] and use the
▲ ▼
buttons to adjust [BRIGHTNESS R] and then
[CONTRAST R].
[BRIGHTNESS R]
Adjust the bottom line of the
waveform to 0 %
(0 or 7.5 IRE)
z
Setting range:
−16 to +16
[CONTRAST R]
Adjust the top line of the
waveform to 100 %
(100 IRE)
z
Setting range:
−32 to +32
3) Adjust [FULL SCAN(G)] / [SINGLE LINE
SCAN(G)].
z
Set on [ADVANCED MENU] and use the
▲ ▼
buttons to adjust [BRIGHTNESS G] and then
[CONTRAST G].
[BRIGHTNESS G]
Adjust the bottom line of the
waveform to 0 %
(0 or 7.5 IRE)
z
Setting range:
−16 to +16
[CONTRAST G]
Adjust the top line of the
waveform to 100 %
(100 IRE)
z
Setting range:
−32 to +32
4) Adjust [FULL SCAN(B)] / [SINGLE LINE
SCAN(B)].
z
Set on [ADVANCED MENU] and use the
▲ ▼
buttons to adjust [BRIGHTNESS B] and then
[CONTRAST B].
[BRIGHTNESS B]
Adjust the bottom line of the
waveform to 0 %
(0 or 7.5 IRE)
z
Setting range:
−16 to +16
[CONTRAST B]
Adjust the top line of the
waveform to 100 %
(100 IRE)
z
Setting range:
−32 to +32
Note
z
When a 3D signal is being input (including converting
2D to 3D), the [WAVEFORM MONITOR] cannot be
executed.