In parallel processing mode

 

 

Tf: 400µs (fixed), Tp (1-1000ms): Data output guarantee time (default: 10 ms) 

* Out signal turns off this timing when setting "Parallel I/O Output Reset Condition"

 

to “Reset”. 

1.  Make sure that REND signal is ON and then turn on STRT signal for more than 1 ms. 

2.  PV-T30 turns off REND signal and starts capturing an image. 

 

The delay time occurs from the input of STRT signal until the start of image capture (REND signal is OFF) when 
displaying a live image. 

Make the settings for Capture Delay from the following items.

 

PV-T30 : “main menu” from the select menu > [Camera] > [Capture Delay]     

PVWIN-T30 : 

[Camera] from the Navigation View

 

> [Capture Delay]

   

          

  (Settable range: 0.0 to 999.9 ms)

 

3.  After image capturing is completed, PV turns on REND signal and executes checkers. 

After REND signal turns on, PV-T30 can receive STRT signal (or capture and image). 
At the timing when it starts capturing the next image, input STRT signal. 

4.  As the inspection ends, a result is output through I/O interface and TACT signal is turned on 

after the period of "Tf". 

Obtain a result after more than 1 ms of wait time when TACT signal turns on. 

 

The time from when TACT signal turns on till when the result output (OUT signal) is determined varies 
according to the condition of the connected load or ambient temperature. 

5.  TACT signal turns on for the time of “Tp”, and then turns off for the time of "Tp + Tf". 

You cannot output the next result while the signal is off and the device is in the status of waiting for output. 

6.  OUT signal keeps on status till the next output (Hold), or turns off when TACT signal turns off 

(Reset). 

Make the settings for “

Hold" or “Reset

” 

from the following items.

 

PV-T30

“Environment setting” from the select menu >

 [System Settings] > [Operation] >   

PV-WINT30

[Environment] from the Navigation View → [System Settings] → [Operation-Inspection setting] 

→"Parallel I/O Output Reset Condition" 

7.  After the second image capturing is completed, PV executes checkers. If the first data has been 

output at the time, REND signal is turned on. If it has not, PV waits until the data is output and 
turns on REND signal. 

After REND signal turns on, PV-T30 can receive STRT signal (or capture and image).At the timing when it starts 
capturing the next image, input STRT signal. 

 
 

Summary of Contents for PVWIN-T30

Page 1: ...PVWIN T30 PV T30 instructions manual Support documentation Nov 24 2015 ...

Page 2: ...urned on after the period of Tf When executing synchronous output data output to COM port and Ethernet port or image output as well as I O output REDY signal stays OFF until these outputs complete After REDY signal turns ON the device can receive the next STRT signal Obtain a result after more than 1 ms of wait time when TACT signal turns on The time from when TACT signal turns on till when the re...

Page 3: ... on after the period of Tf Obtain a result after more than 1 ms of wait time when TACT signal turns on The time from when TACT signal turns on till when the result output OUT signal is determined varies according to the condition of the connected load or ambient temperature 5 TACT signal turns on for the time of Tp and then turns off for the time of Tp Tf You cannot output the next result while th...

Page 4: ... and allows capturing the third image after the second image capturing or the first synchronous result output general output through I O and synchronously whichever completed later before outputting the general result and the image of the first inspection is completed ...

Page 5: ...utput OUT signal is determined varies according to the condition of the connected load or ambient temperature 2 STRB signal turns off after the time of Tp passes 3 As the time of Tp passed from STRB signal turns off the second data is output and STRB signal and REDY signal turn on Obtain the second result after more than 2 ms of wait time when STRB signal turns on When synchronous output is operat...

Page 6: ...signal in the time of To 5 PV T30 outputs the second last data in 100μsec Td after turning off ACK signal 6 As the time of Tf passed from data output turn on STRB signal and REDY signal When synchronous output is operated in addition to I O output including data output to COM port and Ethernet port and inspection image output REDY signal stays OFF until the operation is completed 7 As for an exter...

Page 7: ...lt In addition the reversed value of judgment of JDC001 is automatically referred to JDC001 Creating a Calculation 1 Select INSPECTION Judgement from the menu bar Judgement window is displayed 2 Select a type of Judgement to set by Type Judgement has two types as below Select them in accordance with your purpose JDC External The judgement result can be output to the external device JRC Internal Th...

Page 8: ...esults totally 5 Enter an operation expression Up to 16 items and 560 characters can be set If you selected a wrong item delete it with the F2 key and reregister the expression Moving the cursor onto an item displays the information of the item in the expression explanation field 6 Enter a comment with the software keyboard as necessary 7 After inputting is completed press the CANCEL key 8 Press t...

Page 9: ...his condition expression is common to all cameras When judgement is NG all images of the cameras which is set to Output will be output Selecting a Condition Expression of Inspection Image Output 1 Select Condition in judgement output setting window Condition setting window is displayed 2 Select Condition column of Image Output Select a judgement type to register No Images are not output No Conditi...

Page 10: ...of available value is 1 to 1000 3 Set Overwrite No Default Terminates image saving Yes Deletes the oldest folder and all images stored in the folder and creates a new folder to continue saving when the number of folders reaches the limit or the space of a SD memory card is used up Outputting through Ethernet interface 1 Select Ethernet from the selectmenu Environment Setting Input Output Image Out...

Page 11: ...ted Because the time of outputting images is included its inspection time is longer than the other two options Asynchronous image output first An inspection is complete before outputting images and then PV T30 outputs images when it can When the interval of START signal input the period between inspection start and the next inspection start is short and Image Output is not completed after several ...

Page 12: ...ixels 640 x 480 pixels 1 2 320 x 240 pixels Approx 1 2 of the case of None 1 4 160 x 120 pixels Approx 1 4 of the case of None 1 8 80 x 60 pixels Approx 1 8 of the case of None Compressed images can be automatically decompressed and retrieved with PV T30 and PVWIN T30 However note that the resolution deteriorates When the used camera is 0 3 Meaga Compact Color Camera ANPVC6030 the image size is 64...

Reviews: