background image

EXPLANATION OF FUNCTIONS

6

٨

Sleep function (Incorporated in all models)

When the sleep input is made Low, the sensor goes into the sleep state 
and the operation can be stopped.
Power consumption during the sleep state is 0.3W max. (Without auxili-
ary sensors).

Notes: 1)

2)

3)

Response time of the sleep input is 50ms.
Reactivation from the sleep state to the operation state takes 0.7 sec. approx. Operation
during this transient state should be avoided.
When the sleep function is not used, keep the sleep input wire open or insulated and pre-
vent contact with other wires.

٨

Auxiliary area switching function
(Incorporated in PX-24, PX-24ES, PX-23ES and PX-26 only)

When the auxiliary sensors (

PX-SB1

) are connected to the main sensor, 

the auxiliary area can be made effective or ineffective with an external 
input. For details refer to the instruction manual enclosed with auxiliary 
sensor (

PX-SB1

).

Note: When the auxiliary area switching function is not used, keep the auxiliary area switching input 

wire open or insulated and prevent contact with other wires.

Notes: 1)

2)
3)

The sensitivity of the auxiliary sensor is not changed by this function.
The sensitivity cannot be adjusted beyond the range set by the manual adjuster.
When the external sensitivity adjustment function is not used, keep the external sensitivity 
adjustment input wire open or insulated and prevent contact with other wires.

٨

External sensitivity adjustment function
(Incorporated in PX-24, PX-24ES, PX-23ES and PX-26 only)

The sensitivity can be adjusted, within the range set by the manual sen-
sitivity adjuster, by an analog voltage (0 to +5V) applied to the external 
sensitivity adjustment input. The sensitivity varies with the magnitude of 
the applied voltage.

0V

+5V, or open

Minimum

Maximum

Max. sensitivity set by 
the manual adjuster

Input voltage

Sensitivity

Note: The extraneous light monitor output is not incorporated with a short-circuit protection circuit. Do 

not connect it directly to a power supply or a capacitive load.

٨

Extraneous light monitor function
(Incorporated in PX-24, PX-24ES, PX-23ES and PX-26 only)

If the sensor receives modulated light other than its own (including auxili-
ary sensor's) light, the extraneous light monitor output turns ON. The op-
eration of the extraneous light monitor output has absolutely no affect on 
sensing. It is useful in recognizing presence of other sensors near this 
sensor in case of intersecting AGV paths, etc.

Emitter

Ū
ȷ

External control function
(Incorporated in PX-24ES and PX-23ES only)
PX-24ES

 and 

PX-23ES

 incorporate an external control function. Set the 

external control function selection switch on the adjustment panel to 
'EXT.' side. Then, the sensing area of the main sensor can be selected 
by external signals.

Sensing area

All areas ineffective

Center area effective

Center and left / right adjacent OUT 1 areas effective

Center, right and adjacent left / right OUT 1 areas effective

Center, left and adjacent left / right OUT 1 areas effective

All areas effective

Center, right and adjacent right OUT 1 areas effective

Center left and adjacent left OUT 1 areas effective

Setting method

Input 1

Input 2

Input 3

L

L

L

H

L

L

L

H

L

H

H

L

L

L

H

H

L

H

L

H

H

H

H

H

Area selection input

L: Low (0 to 1V), H: High (4.5 to 31V, or open)

Notes: 1)

2)

Response time of area the selection input is 80ms.
Set the external control selection switch to 'EXT.' side.

INT. D ON R

L

EXT. L ON

OFF

٨

Automatic interference prevention function

In case several sensors are used at the same place, take care that the 
number of sensors from which beams may be simultaneously incident is 
25 sensors or less.

Simultaneously incident beam
from up to 25 sensors.

Total of 26 sensors can be used at 
the same place.

٨

٨

The models listed under “

SPECIFICATIONS

” come with CE 

Marking.
As for all other models, please contact our office.

Contact  for CE

<Until June 30 ,2013>
Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
<From July 1 ,2013>
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany

1

INTENDED PRODUCTS FOR CE MARKING

7

http://panasonic.net/id/pidsx/global

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2012

Overseas Sales Division (Head Office) 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 
Phone: +81-568-33-7861  FAX: +81-568-33-8591

About our sale network, please visit our website.