5.1.6. HOW TO INITIALIZE MEMORY IC
After the Memory IC (IC6004) or TV/VCR Main C.B.A. is
replaced, be sure to set the Default value to Memory IC as
shown in "Memory IC Reference Table" below.
1. Press and hold STOP, PLAY, and VOL DOWN buttons on
the unit together over 5 seconds with no cassette inserted.
The
adjustment
overlay
will
appear
to
Enter
EVR
Adjustment mode.
Fig. 4-1
2. Set the Default value of all Control functions using a remote
control as shown in "Memory IC Reference Table."
Note:
For Selecting Control functions and setting Default
value, refer to "HOW TO ENTER EVR ADJUSTMENT
MODE" and "HOW TO ENTER EVR PG SHIFTER
ADJUSTMENT MODE" in ELECTRICAL ADJUSTMENT
procedures.
Fig. 4-2
3. Press and hold STOP, PLAY, and VOL DOWN buttons on
the unit together over 5 seconds again or press the
POWER button OFF to release EVR Adjustment Mode.
The Default value will be written to Memory IC (IC6004).
4. Perform
all
EVR
Adjustments.
(Refer
to
"EVR
ADJUSTMENT
WITH
THE
REMOTE
CONTROL"
in
ELECTRICAL ADJUSTMENT procedures.)
15
PVQ-1310 / PV-C1320 / PV-C1330W / VV-1300 / VV-1310W / PV-C1340 / PV-C1350W / PV-C2010 / PV-C2020 / PV-C2030W / VV-2000 / PV-C2060