background image

Model No. 

 

      

READ AND SAVE THESE INSTRUCTIONS

Thank you for purchasing this Panasonic product. 

Please read these instructions carefully before attempting to 

install, operate or service the Panasonic product. Please 

carefully read the “GENERAL SAFETY INFORMATION”. 

Failure to comply with instructions could result in personal 

injury or property damage. Please explain to users how to 

operate and maintain the product after installation and this 

manual should be presented to users. Please retain this 

manual for future references.

RG-T810LA

 The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage 
 caused when the denotation is disregarded and improper use is performed. 

To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always 
observe the following safety precautions.

WARNING

CAUTION

Denotes a potential hazard that could result in serious injury or death.

Denotes a hazard that could result in minor injury.

Denotes a hazard that could result in property damage.

The following symbols are used to classify and describe the type of instructions to be observed.

This symbol is used to alert users not to disassemble the equipment.

This symbol is used to alert users to make sure of grounding when using the equipment with the grounding 
terminal.

This symbol is used to alert users to a specific operating procedure that must be followed in order to 
operate this unit safely.

This symbol is used to alert users to a specific operating procedure that must not be performed.

See page 12 for “Panasonic Warranty Sheet”.

GENERAL SAFETY INFORMATION

Ventilating Fan

INSTALLATION INSTRUCTIONS

T8 1 0 L1 4 2 0 A

Summary of Contents for RG-T810LA

Page 1: ... of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions WARNING CAUTION Denotes a potential hazard that could result in serious injury or death Denotes a hazard that could result in minor injury Denotes a hazard that could result in property damage The following symbols are used to classify and describe the type of instructions t...

Page 2: ... Ducted exhaust fans must always be vented to the outdoors Make sure that the electric service supply voltage is AC 120 V 60 Hz Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Administration OSHA CAUTION Always disconnect the power source before working on or near the fan motor light fixture or junction box These model...

Page 3: ...nsumes around 0 1 to 0 4 W These products are listed by UL under UL file No E78414 FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15B of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio freq...

Page 4: ...nd carefully remove the unit from carton Refer to the Supplied Accessories list to verify that all parts are present 5 1 for spare Grille Long screw ST4 2X30 Installation instructions Warranty sheet No No Part name Part name PCB box Blower assy Blade Pick A Flow switch LED lamp Grille Adaptor Junction box Connector plate Damper Suspension bracket Fan body 4 DESCRIPTION CONTINUED UNPACKING SUPPLIED...

Page 5: ...y efficient than the minimum ENERGY STAR requirements These products employ innovative state of the art technologies that provide a number of customizable unique features that lead to improved indoor air quality Please read this manual first in order to realize the benefits of this customizable modular fan 5 Night Light Pick A Flow switch Air volume option CFM 80 100 80 CFM Factory setting This pr...

Page 6: ...circular exhaust duct to fit the adaptor then slip it onto adaptor and secure it with clamps or ties and seal it with mastic or approved foil tape 4 inch Squeeze Note If using 3 inch round duct please purchase the 26 gauge steel Panasonic 4 Oval 3 Round reducer from our representative Open knock out hole 1 Before installation please remove the tape which protects the damper during shipping and acc...

Page 7: ... wires Mount junction box cover carefully so that lead wires are not pinched Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Connect wires 3 Adaptor Junction box cover Knock out hole Circular duct Mastic or approved foil tape 3 1 Finish ceiling work 1 Unit inches mm After finishing the ceiling job fill gap between flange and ceiling with caulk or other sealant...

Page 8: ...p 2 and 3 of INSTALLATION I P 6 7 Insert one mounting spring into slot If not the grille may not be installed Connect the LED lamp wire to fan body Adjust Pick A Flow switch Refer to explanation under FEATURES Page 5 2 3 4 Slot Mounting spring Pick A Flow switch LED lamp wire 3 2 4 Install grille Drywall Mounting spring Gloves Grille 1 Insert the mounting springs into the slot as shown to mount gr...

Page 9: ...not immerse motor or LED lamp in water when cleaning Do not soak resin parts in water over 140 F 60 C Routine maintenance must be done every year Please wear gloves during the cleaning work Disconnect power supply before working on unit 9 After finishing the wall job fill gap between flange and wall with caulk or other sealant to prevent air leakage INSTALLATION II WALL MOUNTING CONTINUED MAINTENA...

Page 10: ...chen detergent remove any dirt from fan body Wipe dry with a clean cloth Reinstall grille after finishing NOTE The grille should be dry after cleaning 3 2 1 Clean grille Don t put into water Use non abrasive kitchen detergent wipe dry with a clean cloth Remove dust and dirt from fan body using a vacuum cleaner Gloves Drywall 2 Vacuum cleaner Drywall 3 Gloves 10 MAINTENANCE CLEANING Slot Mounting s...

Page 11: ... box to drywall Short piece of flexible duct helps alignment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints Insulation Foil tape tightly covers all metal duct joints glue PVC joints Check according to the following table and correct the problem If the fan still does not work correctly please disconnect the power source and contact the dealer PROBLEM CAUSE ACTIO...

Page 12: ...an implied warranty lasts so the above exclusions or limitation may not apply to you Obtain Product Information and Operating Assistance locate your nearest distributor or make Customer Service and Literature requests by visiting our Web Site at us panasonic com ventfans or send your request by E mail to ventfans us panasonic com You may also contact us directly at 1 866 292 7299 Monday Friday 9 a...