Error code
Possible symptom
Description of problem
U02
Power supply cut
·
During operation, when PDET switches to OFF (PDET - 1.534V) due to fall of power supply voltage
fall, the power supply will be automatically switched OFF.
·
If REM_STBY = L, VCCDET = H the system shall be judged to have low battery and [......UO2] shall
be displayed for 10 seconds.
·
To check REM_STBY and VCCDET, chattering check will be read-in twice 1 sec after PCONT is set
to L.
·
Power supply state shall be checked using REM_STBY and VCCDET inputs. If power ON is
executed from power OFF (REM_STBY = L and VCCDET = H), error number [......UO2] will be
displayed for 5 seconds. This error number will not be memorized.
F15
CD REST_SW
abnormal
·
At initial setting of CD traverse position, if REST_SW ON is not detected even though the fail safe
timer time is over (10 sec), this is memorized as an error and the error number can be cleared only
at the start up of micro-p after reset.
H15
CD OPEN_SW
abnormal
·
During normal operation, if CD OPEN_SW ON is not detected within 4 sec, then H15 will be
memorized in memory. The error code can be cleared only at the start up of micro-p after reset.
H01
DECK operation
abnormal (reel motor,
solenoid, and
MODE_SW)
(provisional)
·
During normal operation, if mechanism error process is executed once by mode switch against the
same deck operation, it is judged as mechanism abnormality and this is memorized as an error.
·
Conditions for judging mechanism error:
−
Mode switch ON is not detected 800 ms after plunger activation for PLAY / REC process.
−
Mode switch ON is not detected 800 ms after plunger activation for FF / REW process / Mode
switch OFF is not detected 800 ms after plunger activation after detecting Mode SW ON / Mode
Switch ON is not detected 800 ms after detecting Mode switch OFF.
−
If Mode switch comes ON at STOP / PAUSE state (normal condition), this is judged as an Error:
1.
Main purpose for this Self Diagnosis is to diagnose a partial short of the deck.
2.
Mechanical error process caused by EJECT operation will not be counted.
3.
This error number can be cleared only at the start up of micro-p after reset.
F26
Communication
between CD servo LSI
and microp abnormal
·
At the time of switching to CD function, SENSE = H will be detected using DTMS system setting
command. If the error is memorized when SENSE = L is not detected within fail safe timer time (20
sec), [F26] will be displayed simultaneously. This display will be retained if the power is ON and at
CD function. If this error occurs, CD operation afterward cannot be executed as in the case of
[NO.DISC.]. This error number can be cleared only at the start up of micro-p after reset.
14.1.5. Self-diagnosis mode Deck Mechanism
·
Activate the Self Diagnosis mode for the Deck and the following Self Diagnosis will be conducted.
Error Code
Description
H01:
If MODE_SW abnormal is detected during normal operation, it will be memorized. The detection and memory
shall be done for Deck.
H02:
RECINH_SW abnormal.
H03:
HALF_SW abnormal.
F01:
Reel pulse abnormal.
·
Operating Procedures
1. Activate the Self Diagnosis mode with the Deck unloaded.
2. The test mode will be displayed ([T] at the 1st digit shows TEST) and detection shall be executed to check RECINH_SW,
HALF_SW are in the OFF state (the tape counter display is retained).
3. Load a cassette tape (with recording preventive tab present) into the deck and close the cassette holder.
4. At this instant with the cassette loaded in, RECINH_SW, HALF_SW will be checked and confirmed at this stage by the software.
Press FF key to proceed the self-diagnosis. The FF operation will stop automatically after 3 sec. If abnormal operation is
detected, the tape will stop automatically after 1 sec. During the FF operation, the Reel Pulse will be checked by the software.
5. After the tape stops, the Error codes will be displayed by toggling the STOP
n
key. (For a more detailed explanation, refer to
Figure 14-2).
31
RX-ES29GC / RX-ES29GS / RX-ES29GT
Summary of Contents for RX-ES29GS
Page 4: ...2 Caution for AC Mains Lead 4 RX ES29GC RX ES29GS RX ES29GT ...
Page 9: ...10 Operation Procedures 10 1 Main unit 9 RX ES29GC RX ES29GS RX ES29GT ...
Page 10: ...10 2 Remote control 10 RX ES29GC RX ES29GS RX ES29GT ...
Page 11: ...11 Information on MP3 11 RX ES29GC RX ES29GS RX ES29GT ...
Page 22: ...22 RX ES29GC RX ES29GS RX ES29GT ...
Page 24: ...24 RX ES29GC RX ES29GS RX ES29GT ...
Page 25: ...25 RX ES29GC RX ES29GS RX ES29GT ...
Page 28: ...28 RX ES29GC RX ES29GS RX ES29GT ...
Page 37: ...Example of LCD Display 37 RX ES29GC RX ES29GS RX ES29GT ...
Page 40: ...40 RX ES29GC RX ES29GS RX ES29GT ...
Page 42: ...16 2 Main P C B 42 RX ES29GC RX ES29GS RX ES29GT ...
Page 43: ...43 RX ES29GC RX ES29GS RX ES29GT ...
Page 70: ...24 Troubleshooting Flowchart CD Section Circuit 70 RX ES29GC RX ES29GS RX ES29GT ...
Page 71: ...71 RX ES29GC RX ES29GS RX ES29GT ...
Page 77: ...25 3 Cabinet Part List 25 3 1 Cabinet Parts Location 77 RX ES29GC RX ES29GS RX ES29GT ...