114
S-ICX (International) issued April 2002
S-ICX-64-700
Chapter 4. User Maintenance
Section 700 - Operation
To set the Verified Account code:
Action
Result
1. If not already in User Maintenance mode, enter User Main-
tenance mode. (See “To enter User Maintenance mode:” on
page 79.)
81-
User MAINT
displays
2. At the
81
level, enter
04
.
3. Press the
HOLD
key.
8104-
Verified ACCD
displays
4. Press the
HOLD
key.
Table Number
displays
5. Enter the Verified Account table number (
001
-
500
).
6. Press the
HOLD
key.
XXX-
Verified ACCD
displays (where XXX
= account code table number)
7. Press the
HOLD
key.
0001 : AAAAAAAAAAA
XXX:Account Code
displays (where
AAAAAAAAAAA = current account
code and XXX = account code table
number)
8. Enter up to ten-digit Verified Account Code. (All Verified
Account Codes must be unique. If there is a matching entry
entered, the System will not accept the entry and will double
beep.)
Note:
To clear an entry or existing data, press the FL/R key.
9. Press the
HOLD
key.
0002 :X
XXX:TRS Class
displays (where X =
TRS Class)
10. Enter the TRS (Call Barring) Class to be associated with
the Verified Account Code entry.
11. Press the
HOLD
key to store the entry.
0001 :YYY
displays (where YYY = the
next account code table number)
12. To add additional Verified Account numbers, press the
volume up or down key or press the
HOLD
key to move to
the desired Verified Account table number.
Desired Verified Account table number
displays
13. Repeat steps 8-12 until all Verified Account numbers are
entered.
14. Press the MEMORY key to exit the entry mode
Table Number
15. To return to the top menu level (
81
), press the
PROG
key.
OR...
To exit the User Maintenance mode, press the
ON/OFF
key.
81-
User MAINT
displays
OR...
ON/OFF
LED goes off