RELAY REPLACEMENT

10

The relay has an electrical, as well as, a mechanical life.

In case there is any difficulty in operation due to relay contact 

wear and tear or contact welding, replace the relay.

Make sure to use the following relay:

Using the attached relay removal 

key, replace the relay as per the 

procedure given below.

Align and insert the relay removal 

key in the socket groove of the 

relay to be removed.

Pull up the relay removal key to 

remove the relay from the relay 

socket.

Slide the relay removal key 

sideways to detach the relay from 

the key.

Insert the new relay reliably into 

the socket, matching the socket 

terminal direction.

Manufacturer

Part No.

Panasonic Corporation

APAN3124

Slide

Pull up

Insert

Relay removal key

Relay to be replaced

Insert

reliably

New relay

DIMENSIONS (Unit: mm)

11

SL-TPR4 / 4 channel relay output type

SL-TPR8 / 8 channel relay output type

30 32

±

1

11.5

16

1.4

Cover

Relay removal key

48

22

3.7

55

±

1

59

3.9

67

±

1

5.5

±

0.6

11

Switch cap

2-

φ

4.5 mounting holes

Transmission

indicator

(Green)

φ

2.5

×

4-core  flat cable 0.6m long

4-operation indicators (Orange)

35.4

8

11.5

Suitable for 35mm width DIN rail

30 32

±

1

11.5

16

1.4

Cover

Relay removal key

59 67

±

1

3.9

5.5

±

0.6

78

85.5

±

1

22

3.7

11

Switch cap

2-

φ

4.5 mounting holes

Transmission

indicator

(Green)

φ

2.5

×

4-core  flat cable 0.6m long

8-operation indicators (Orange)

35.4

8

11.5

Suitable for 35mm width DIN rail

Please refer to the '

S-LINK Design Manual

' for details of the 

entire 

S-LINK

 system.

https://panasonic.net/id/pidsx/global

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2018

Overseas Sales Division (Head Office) 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 

Phone: +81-568-33-7861  FAX: +81-568-33-8591

For sales network, please visit our website.