1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω
and 5.2
Ω
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
Fig. 1
1.1.2. Leakage Current Hot Check (See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a 0.15µF capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
1.2. Before Repair and Adjustment
Disconnect AC power, discharge Power Supply Capacitors C707 & C1706 through a 10
Ω
, 1W resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 230 V - 240 V, 50Hz in NO SIGNAL mode should be 200 ~ 800 mA.
1.3. Protection Circuitry
The protection circuitry may have operated if either of the following conditions is noticed:
*No sound is heard when the power is supplied.
*Sound stops during a performance.
The functions of this circuitry is to prevent circuitry damage, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of this unit are used.
If this occurs, follow the procedure outlined below:
1. Press the STANDBY
/ON button, switch to STANDBY mode.
4
SA-HT40EE
Summary of Contents for SA-HT40EE
Page 7: ...5 Operation Procedures 5 1 Remote Control Operation 7 SA HT40EE ...
Page 8: ...5 2 Main Unit Operation 8 SA HT40EE ...
Page 9: ...9 SA HT40EE ...
Page 10: ...6 1 Music Port 6 New Features 10 SA HT40EE ...
Page 14: ...8 3 Main Parts Location 14 SA HT40EE ...
Page 23: ...9 3 Checking the Panel P C B Music Port P C B and Volume P C B 23 SA HT40EE ...
Page 24: ...9 4 Checking the Main P C B Power P C B Digital Amp P C B 24 SA HT40EE ...
Page 32: ...32 SA HT40EE ...
Page 34: ...SA HT40EE 34 ...
Page 38: ...38 SA HT40EE ...
Page 44: ...SA HT40EE 44 ...
Page 48: ...SA HT40EE 48 ...
Page 50: ...SA HT40EE 50 ...
Page 58: ...SA HT40EE 58 ...
Page 61: ...17 Exploded Views 17 1 Cabinet Parts Location SA HT40EE 61 ...
Page 62: ...17 2 Packaging SA HT40EE 62 ...