No. Error
ErrorDisplay Problem condition
1 MODE SWdetection error
H01
Faulty operation of cassette mechanism.Faulty contact or short-circuit of mechanism mode switch (S951,
S971).
2 REC INH SWdetection
error
H02
Recording not possible.Faulty contact or short-circuit of REC INH switch (S974, S975).
3 HALF SWdetection error
H03
Playback cannot perform.Faulty contact or short-circuit of HALF siwtch (S952, S972).
4 Reel Pulsedetection error
F01
The tape advances slightly and then stops.Faulty reel pulse, faulty hole detect IC (IC951, IC971).
5 TPS abnormal
F02