4.4 Command List
WUME-SCHG1ETC-2
4-23
Command
Attribute
Name
Response/Setting parameter
HG-T
series
0x0022
R
Maximum value during P-P
measurement
Integer indicating minimum resolution units of
controller.
If the measurement mode is not P-P, a judgment
value is output.
-1999999 to 1999999
0x0023
R
Minimum value during P-P
measurement
Integer indicating minimum resolution units of
controller.
If the measurement mode is not P-P, a judgment
value is output.
-1999999 to 1999999
0x0024 to 0x003F
-
System reserved
Do not use.
0x0040
R/W Preset (PRESET)
0: OFF
1: ON
0x0041
R/W Preset value (PR. VAL)
Integer indicating minimum resolution units of
controller.
-1999999 to 1999999
0x0042
R/W Preset data selection
(PR.OBJ)
0: Normal measured value (NORM.V)
1: Judgment value (JUDGE.V)
0x0043
R/W Preset save (PR.SAVE)
0: OFF
1: ON
0x0044
R/W Label 1 (LABEL)
Label [1st to 4th character]
Part of character code is usable. (Note 1)
0x0045
R/W Label 2 (LABEL)
Label [5th to 6th character]
Part of character code is usable. (Note 1)
0x0046
R/W Average count (SPEED)
0: 1 time
1: 2 times
2: 4 times
3: 8 times
4: 16 times
5: 32 times
6: 64 times
7: 128 times
8: 256 times
9: 512 times
10: 1024 times
0x0047
R/W Measurement direction
(DIRECT)
0: TOP
1: BOTTOM
0x0048
R/W Alarm delay count (DELAY)
Delay count: 1 to 1000
0x0049
R/W Teaching type (TEACH)
0: 1-point teaching
1: 2-point teaching
2: 3-point teaching
0x004A
R/W Input all (ALL IN)
0: Individual input
1: Simultaneous input
0x004B
R/W External input (EXT.IN)
0: Preset / Reset / Trigger (P/R/T)
1: Bank A / Bank B / Preset (BANK/P)
2: Bank A / Bank B / Reset (BANK/R)
3: Bank A / Bank B / Trigger (BANK/T)
4: Preset / Trigger / Laser emission stop (P/T/L)
0x004C
R/W External output (EXT.OUT)
0: 3-value (3VAL)
1: 2-value (2VAL)
2: Logic (LOGIC)
3: Logic 2 (LOGIC2)
0x004D
R/W Analog scaling (ANALOG)
0: Default
1: Free
0x004E
R/W Scaling upper limit value
(ANA.HI)
Integer indicating minimum resolution units of
controller.
-1999999 to 1999999
Summary of Contents for SC-HG1-ETC
Page 2: ...WUME SCHG1ETC 2 2 MEMO ...
Page 14: ...WUME SCHG1ETC 2 1 8 MEMO ...
Page 20: ...WUME SCHG1ETC 2 2 6 MEMO ...
Page 30: ...WUME SCHG1ETC 2 3 10 MEMO ...
Page 80: ...WUME SCHG1ETC 2 4 50 MEMO ...
Page 90: ...WUME SCLG2CEFP 2 5 10 MEMO ...
Page 91: ...6 1 6 Specification and Dimensions 6 1 Specifications 6 2 6 2 Dimensions 6 3 ...
Page 94: ...WUME SCHG1ETC 2 6 4 MEMO ...
Page 95: ...7 1 7 Warranty 7 1 Important Information about Order and Use of This Product 7 2 ...
Page 98: ...WUME SCHG1ETC 2 7 4 MEMO ...
Page 101: ...9 1 9 Troubleshooting 9 1 Error Codes and Solutions 9 2 9 2 Solutions to Problems 9 4 ...
Page 108: ...10 2 Sample Program WUME SCHG1ETC 2 10 4 10 2 Sample Program 1 2 3 4 5 6 ...
Page 114: ... MEMO ...
Page 115: ... MEMO ...