9.1 Error Codes and Solutions
WUME-SCHG1ETC-2
9-2
Solutions to frequently encountered problems and errors are described below.
9.1 Error Codes and Solutions
Notifica
-
tion source Code
Description
Action method
SC-HG1-ETC
100 This command cannot be used with
the target controller.
Check an appropriate command by referring to
101 An out-of-range parameter setting
was requested.
The parameter setting is invalid.
Check an appropriate parameter setting by referring to
102
A write request was issued with
settings that cannot be used with
the target controller.
The parameter setting is invalid.
Check an appropriate parameter setting by referring to
103
A read request was issued with
settings that cannot be used with
the target controller.
The parameter setting is invalid.
Check an appropriate parameter setting by referring to
200 No sensor head is connected.
Check the connection state of the sensor head.
300
The system received a command
that cannot be used because there
is no calculation setting.
Set the master unit to calculation mode by referring to
the user’s manual of the sensor.
301
The system received a command
that cannot be used because P-P or
P-P/2 is not set in hold settings.
Set the master unit to P-P or P-P/2 by referring to the
user’s manual of the sensor.
400
When a calibration was executed,
an alarm, indeterminate state, or
out-of-display-range error occurred.
The sensor head value is invalid. Check the state of the
sensor head.
401 A calibration was not implemented
normally.
A calibration failed.
Check the setup procedure by referring to the user’s
manual of the sensor.
500
When teaching was executed, an
alarm, indeterminate state, or out-
of-display-range error occurred.
The sensor head value is invalid. Check the state of the
sensor head.
501 Teaching was not implemented
normally.
Teaching failed.
Check the setup procedure by referring to the user’s
manual of the sensor.
600
When a preset was executed, an
alarm, indeterminate state, or out-
of-display-range error occurred.
The sensor head value is invalid. Check the state of the
sensor head.
700
When an attempt was made to load
or save data from/to a bank, the
bank number was out of range.
Send appropriate parameter settings by referring to the
user’s manual of the sensor.
800 Data failed to be written to internal
memory.
Turn the power OFF and then ON to initialize the con
-
troller.
If the controller does not recover even after the above
action is taken, consult your Panasonic representative.
4095 Before receiving a response to a re-
quest, the user sent a next request.
Resend the command after waiting for a certain time
period.
900 A response to a request has timed
out.
Check the connection state between the communication
unit and the controller.
1900
This product failed to communicate
with controllers.
Switch OFF the power, make sure the controllers are
connected correctly, and then switch ON the power again.
2000
Switch OFF the power, make sure the controllers are
connected correctly, and then switch ON the power again.
2200
The specified destination unit cannot be found.
Switch OFF the power, make sure the controllers are
connected correctly, and then switch ON the power again.
Summary of Contents for SC-HG1-ETC
Page 2: ...WUME SCHG1ETC 2 2 MEMO ...
Page 14: ...WUME SCHG1ETC 2 1 8 MEMO ...
Page 20: ...WUME SCHG1ETC 2 2 6 MEMO ...
Page 30: ...WUME SCHG1ETC 2 3 10 MEMO ...
Page 80: ...WUME SCHG1ETC 2 4 50 MEMO ...
Page 90: ...WUME SCLG2CEFP 2 5 10 MEMO ...
Page 91: ...6 1 6 Specification and Dimensions 6 1 Specifications 6 2 6 2 Dimensions 6 3 ...
Page 94: ...WUME SCHG1ETC 2 6 4 MEMO ...
Page 95: ...7 1 7 Warranty 7 1 Important Information about Order and Use of This Product 7 2 ...
Page 98: ...WUME SCHG1ETC 2 7 4 MEMO ...
Page 101: ...9 1 9 Troubleshooting 9 1 Error Codes and Solutions 9 2 9 2 Solutions to Problems 9 4 ...
Page 108: ...10 2 Sample Program WUME SCHG1ETC 2 10 4 10 2 Sample Program 1 2 3 4 5 6 ...
Page 114: ... MEMO ...
Page 115: ... MEMO ...