4.3 Command Transmission Procedure
WUME-SCHG1ETC-2
4-11
4.3 Command Transmission Procedure
You must send commands when checking controller operating statuses or changing settings.
4.3.1 Read Command
If the read command is sent, operating statuses or settings will be returned from each unit (con-
troller).
1.
Use 1600:0D to set a sensor response data switching request in the command.
2.
Use 1A00:0D to check that the sensor response data switching response is a command.
3.
Use 1600:40 to 1600:4E to set the unit (controller) to which the command is to be sent.
4.
Set the command code to be sent in 1600:50.
5.
Set the command data (parameter settings) to be sent in 1600:51 to 1600:5F.
6.
Set the transmission request flag in 1600:01. (The command will be sent.)
7.
Check the transmission completion flag in 1A00:01 and the error flag in 1A00:02 to see that
the command has been completed successfully.
8.
Check that the command response sensor in 1A00:61 to 1A00:6F and the command re-
sponse code in 1A00:71 match the contents of the sent request and then read the response
data in 1A00:72 to 1A00:80.
9.
To send another command successively, clear the transmission request flag in 1600:01,
check that the transmission completion flag in 1A00:01 has been cleared, and then repeat
the procedure starting from Step
3.
RxPDO
Name
Description
1600:01 Send Command
Command request: Transmission request
1600:02 Write Flag
Command request: Write flag
1600:03 Non use
Unused
~
1600:08 Non use
Unused
1600:09 Judge Value Mode
Sensor response data switching request:
Judgment value
1600:0A Normal Value Mode
Sensor response data switching request:
Normal measured value
1600:0B Calculation Value Mode
Sensor response data switching request:
Calculated value
1600:0C Head Value Mode
Sensor response data switching request:
Sensor head value
1600:0D Command Mode
Sensor response data switching request:
Command
1600:0E Non use
Unused
1600:0F Error Code
Sensor response data switching request:
Error code
1600:10 Non use
Unused
~
6.
After setting
the command
to be sent, set
a transmission
request.
1.
Set in the
command.
Summary of Contents for SC-HG1-ETC
Page 2: ...WUME SCHG1ETC 2 2 MEMO ...
Page 14: ...WUME SCHG1ETC 2 1 8 MEMO ...
Page 20: ...WUME SCHG1ETC 2 2 6 MEMO ...
Page 30: ...WUME SCHG1ETC 2 3 10 MEMO ...
Page 80: ...WUME SCHG1ETC 2 4 50 MEMO ...
Page 90: ...WUME SCLG2CEFP 2 5 10 MEMO ...
Page 91: ...6 1 6 Specification and Dimensions 6 1 Specifications 6 2 6 2 Dimensions 6 3 ...
Page 94: ...WUME SCHG1ETC 2 6 4 MEMO ...
Page 95: ...7 1 7 Warranty 7 1 Important Information about Order and Use of This Product 7 2 ...
Page 98: ...WUME SCHG1ETC 2 7 4 MEMO ...
Page 101: ...9 1 9 Troubleshooting 9 1 Error Codes and Solutions 9 2 9 2 Solutions to Problems 9 4 ...
Page 108: ...10 2 Sample Program WUME SCHG1ETC 2 10 4 10 2 Sample Program 1 2 3 4 5 6 ...
Page 114: ... MEMO ...
Page 115: ... MEMO ...