4.8 Other Precautions
WUME-SCHG1ETC-2
4-49
4.8 Other Precautions
• For the
HG-T
series controllers, measured values will be temporarily reset during measurement if
the following commands are written.
Command code
Name
Remarks
0x001E
BANK LOAD execution (LOAD)
―
0x0046
Average count (SPEED)
―
0x0047
Measurement direction (DIRECT)
―
0x0048
Alarm delay count (DELAY)
For write only
0x0059
Sampling cycle (SAMPLI)
For write only
0x0300
Operation mode (OP.MODE)
For write only
0x0304
Sensitivity setting
For write only
0x0305
Judgment level (JDG.LVL)
For write only
0x0306
Judgment filter (JDG.FIL)
For write only
0x030C
Stain check (STA.CHK)
For write only
0x030D
Stain threshold (STA.THR)
For write only
0x031E
Sensor head cumulative run time
(HD.TIME)
―
0x0325
Reverse insertion check (DIR.CHK)
For write only
• For the
HG-T
series controllers, approximately five seconds after the power is turned ON, measured
values are synchronously collected from the heads connected to each controller.
Summary of Contents for SC-HG1-ETC
Page 2: ...WUME SCHG1ETC 2 2 MEMO ...
Page 14: ...WUME SCHG1ETC 2 1 8 MEMO ...
Page 20: ...WUME SCHG1ETC 2 2 6 MEMO ...
Page 30: ...WUME SCHG1ETC 2 3 10 MEMO ...
Page 80: ...WUME SCHG1ETC 2 4 50 MEMO ...
Page 90: ...WUME SCLG2CEFP 2 5 10 MEMO ...
Page 91: ...6 1 6 Specification and Dimensions 6 1 Specifications 6 2 6 2 Dimensions 6 3 ...
Page 94: ...WUME SCHG1ETC 2 6 4 MEMO ...
Page 95: ...7 1 7 Warranty 7 1 Important Information about Order and Use of This Product 7 2 ...
Page 98: ...WUME SCHG1ETC 2 7 4 MEMO ...
Page 101: ...9 1 9 Troubleshooting 9 1 Error Codes and Solutions 9 2 9 2 Solutions to Problems 9 4 ...
Page 108: ...10 2 Sample Program WUME SCHG1ETC 2 10 4 10 2 Sample Program 1 2 3 4 5 6 ...
Page 114: ... MEMO ...
Page 115: ... MEMO ...