Schottky Barrier Diodes (SBD)

1

Publication date: April 2004

SKH00035BED

MA2Z720

Silicon epitaxial planar type

For high frequency rectification

Features

Forward current (Average) I

F(AV)

 

=

 500 mA rectification is

possible

High-density mounting is possible

Absolute Maximum Ratings  

T

a

 

=

 

25

°

C

Parameter

Symbol

Rating

Unit

Reverse voltage

V

R

40

V

Maximum peak reverse voltage

V

RM

40

V

Forward current (Average)

I

F(AV)

500

mA

Non-repetitive peak forward

I

FSM

2

A

surge current 

*

Junction temperature

T

j

125

°

C

Storage temperature

T

stg

55 to

 +

125

°

C

Marking Symbol: 2L

Parameter

Symbol

Conditions

Min

Typ

Max

Unit

Forward voltage

V

F

I

F

 

=

 500 mA

0.55

V

Reverse current

I

R

V

R

 

=

 35 V

100

µ

A

Terminal capacitance

C

t

V

R

 

=

 0 V, f 

=

 1 MHz

60

pF

Reverse recovery time 

*

t

rr

I

F

 

=

 I

R

 

=

 100 mA

5

ns

I

rr

 

=

 0.1 I

R

, R

L

 

=

 100 

Electrical Characteristics

 

 T

a

 

=

 

25

°

C

 

±

 

3

°

C

Bias Application Unit (N-50BU)

90%

Pulse Generator
(PG-10N)
R

s

 

50 

Wave Form Analyzer
(SAS-8130)
R

i

 

50 

t

p

 

µ

s

t

r

 

0.35 ns

δ = 

0.05

I

F

 

=

 100 mA

I

R

 

=

 100 mA

R

L

 

=

 100 

10%

Input Pulse

Output Pulse

I

rr

 

=

 0.1 I

R

t

r

t

p

t

rr

V

R

I

F

t

t

A

Unit: mm

1: Anode
2: Cathode
EIAJ: SC-76

SMini2-F1 Package

1.25

±

0.1

0.7

±

0.1

2.5

±

0.2

1.7

±

0.1

0.4

±

0.1

0 to 0.1

(0.15)

0.16

0.5

±

0.1

1

2

+0.1

–0.06

0.35

±

0.1

0 to 0.1

Note) *: The peak-to-peak value in one cycle of 50 Hz sine wave (non-repetitive)

Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.

2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body

and the leakage of current from the operating equipment.

3. Absolute frequency of input and output is 400 MHz.

4.*: t

rr

 measurement circuit

This product complies with the RoHS Directive (EU 2002/95/EC).