11
RQTX1009
ENGLISH
11
ESP
AÑOL
ENGLISH
Troubleshooting guide
Before requesting service, make the following checks. If you are in
doubt about some of the check points, or if the solutions indicated in
the table do not solve the problem, consult your dealer for instructions.
No power
• Ensure the AC mains lead is connected
properly.
No sound
• Adjust the volume.
• Check if mute function is enabled.
• Update your iPod or iPhone with the latest
software.
• The iPod or iPhone was incorrectly inserted
into the dock. Turn off the iPod or iPhone,
remove it from the dock connector. Reinsert
it and turn it on again.
Remote control is
not functioning
• Replace the battery.
• Ensure the iPod or iPhone is seated properly
into the unit.
Distorted sound
• Reduce the volume.
• Set the “EQ” setting of the iPod to “Off” or
“Flat”.
iPod or iPhone
does not charge
• Check the connections. (
\
page 8)
Unable to use PC
synchronisation
• Turn the main unit on.
• Check PC and iPod or iPhone connections.
(
\
page 8, 10)
Specifi cations
AMPLIFIER SECTION
RMS output power stereo mode
Front Ch (both channels driven)
5 W per channel (6
Ω
), 1 kHz, 10% THD
Subwoofer Ch
10 W per channel (6
Ω
), 100 Hz, 10% THD
Total RMS stereo mode power
20 W
TERMINALS SECTION
Music port (rear)
Sensitivity
350 mV, 13.2 k
Ω
Terminal
Stereo, 3.5 mm jack
SPEAKER SECTION
Front speakers
Speaker unit(s)
Impedance: 6
Ω
Full range
4 cm cone type
Input power (IEC)
5 W (Max)
Subwoofer
Speaker unit(s)
Impedance: 6
Ω
Woofer
6.5 cm cone type
Passive radiator (x2)
6.5 cm
Input power (IEC)
10 W (Max)
GENERAL
Power supply
DC 12 V (DC IN terminal)
Power consumption
15.6 W (unit only)
AC adaptor
AC 100 to 240 V, 50/60 Hz
Power consumption
36 W
Dimensions (WxHxD)
175 mm x 138.8 mm x 178.5 mm
Mass 0.85
k
g
Operating temperature range
0°C to +40°C
Operating humidity range
20% to 80% RH (no condensation)
Power consumption in standby mode:
0.7 W (approximate)
Note:
1) Specifi cations are subject to change without notice.
Mass and dimensions are approximate.
2) Total harmonic distortion is measured by the digital spectrum
analyser.
Maintenance
To clean this unit, wipe with a soft, dry cloth.
• Never use alcohol, paint thinner or benzine to clean this unit.
• Before using chemically treated cloth, read the instructions that came
with the cloth carefully.