3-3 Wiring
© Panasonic Industrial Devices SUNX Co., Ltd. 2013 MJE-SF4A No.0038-55V
- 55 -
<Reference>
Use a safety relay unit or an equivalent control circuit in safety for FSD.
Connect the shield to the frame ground (F.G.) without fail. Failure to do so can
cause malfunction due to noise, which can result in serious injury or death.
Further, the wiring should be done in a metal box connected to the frame ground.
Take countermeasure against the system to be applied for this device so as not
to carry out the dangerous performance caused by the earth failure. Failure to do
so could cause invalid for the system stop, resulting in serious body injury or
death.
3-3-1 Power Supply Unit
Make sure to insulate the ends of the unused lead wires.
<Reference>
A specialist who has the required electrical knowledge should perform the wiring.
The DC power supply unit must satisfy the conditions given below.
1
)
Power supply unit authorized in the region where this device is to be used.
2
)
Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage)
conforming to EMC Directive and Low-voltage Directive (only for requiring CE marking
conformation).
3
)
Power supply unit conforming to the Low-voltage directive and with an output of 100VA or less.
4
)
The frame ground (F.G.) terminal must be connected to ground when using a commercially
available switching regulator.
5
)
Power supply unit with an output holding time of 20ms or more.
6
)
In case a surge is generated, take countermeasures such as connecting a surge absorber to
the origin of the surge.
7
)
Power supply unit corresponding to CLASS 2 (only for requiring UL Listing Mark / C-UL US
Listing Mark conformation)
Wire correctly using a power supply unit which conforms to the laws and standards
of the region where this device is to be used. If the power supply unit is
non-conforming or the wiring is improper, it can cause damage or malfunction of
this device.
Summary of Contents for SF4-AH Series
Page 1: ... Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SF4A No 0038 55V 1 ...
Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SF4A No 0038 55V 2 MEMO ...
Page 14: ...Common specifications Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SF4A No 0038 55V 14 ...
Page 17: ...SF4 AH H Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SF4A No 0038 55V 17 ...
Page 19: ...SF4 AH H Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SF4A No 0038 55V 19 ...
Page 21: ...SF4 AH H Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SF4A No 0038 55V 21 ...
Page 23: ...SF4 AH H Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SF4A No 0038 55V 23 ...
Page 78: ... Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SF4A No 0038 55V 78 MEMO ...
Page 80: ......