© Panasonic Industrial Devices SUNX Co., Ltd. 2017
40
Wiring
*S1
Switch S1
●
Emission halt input / Reset input
For manual reset ... Vs to Vs - 2.5V (sink current 5mA or less) : Emission halt (Note), Open: Emission
For auto-reset ... Vs to Vs - 2.5V (sink current 5mA or less) : Emission (Note), Open: Emission halt
●
Interlock setting input, Override input, Muting input A / B, External device monitor input
Vs to Vs - 2.5V (sink current 5mA or less): Valid (Note), Open: Invalid
●
Large multi-purpose indicator input
0 to + 1.5V (source current: 5mA or less): Lights up, Open: Turn OFF
Note: Vs is the applying supply voltage.
<Reference>
●
K1, K2: External device (Forced guided relay or magnetic contactor)
● For more information about wiring, refer to Section 2-5-4 and subsequent sections.