© Panasonic Industrial Devices SUNX Co., Ltd. 2017
68
Adjustment
2) When using emission halt function
This device incorporates the emission halt function. Using this function, it is possible to simulate
the light blocked status.
<Reference>
When the emission halt input / reset input is kept open (for manual reset: connected to 0V, +V),
the emitter stops emitting light. In this condition, if this device operates properly, the control output
(OSSD 1 / 2) of the receiver turns OFF.
: Blinks in orange, : Lights up in red, : Lights up in orange, : Lights up in green, : Turns OFF
Setting procedure and
check items
Indicators
Control output
Emitter
Receiver
OSSD 1 OSSD 2
1
Before power is ON,
Connect the emission
halt input / reset input
to Vs.
(Note 3)
(Note 1)
OFF
2
After power is ON,
Receiver’s control out-
put (OSSD 1 / 2) is ON.
(Normal operation)
(Note 1)
(Note 2)
(Note 2)
ON
Notes: 1) Since the color of the operation indicator changes according to ON / OFF status of the control output
(OSSD 1 / 2), the operation indicator is marked as “OSSD” on the device.
2) The status of the emitter / receiver indicators during operation above shows the case in PNP output set-
ting mode. In case of NPN output setting mode, the NPN indicator (orange) lights up.
3) Vs is the applying supply voltage.