© Panasonic Industrial Devices SUNX Co., Ltd. 2014
26
Mounting
<In case of using side utility mounting bracket MS-SF4BC-3 (optional)>
Step 1 Secure the bracket with two hexagon-socket head bolts [M3 (length: 6mm)]. The tight
-
ening torque should be 0.5N•m.
If installation space is limited, insert a hexagon head bolt [M5 (purchase separately)]
into the side utility mounting bracket and tighten with two hexagon-socket head bolts [M3
(length: 6mm)]. The tightening torque should be 0.5N•m.
Hexagon-socket head bolts
[M3 (length: 6mm)]
(Accessory of
MS-SF4BC-3
)
Main body
Side utility mounting bracket
MS-SF4BC-3
(Optional)
Hexagon head bolt
[M5 (purchase separately)]
Side utility mounting bracket
MS-SF4BC-3
(Optional)
Hexagon-socket head bolts
[M3 (length: 6mm)]
(Accessory of
MS-SF4BC-3
)
Main body
Side utility mounting bracket
MS-SF4BC-3
(Optional)
<Space-saving installation>
Step 2 Mount the side utility mounting bracket on the mounting surface using hexagon-socket
head bolts [M5 (purchase separately)].
If installation space is limited, tighten the hexagon head bolts to secure the product to
the mounting surface.
Hexagon-socket head bolt
[M5 (purchase separately)]
Main body
<Space-saving installation>
Hexagon head bolt
Main body
Note: Use M5 washers (accessory of
MS-SF4BC-3
) when mounting to an aluminum frame.
Ramco National
800-280-6933 | nsales@ramcoi.com
www.panasonicsensors.com