© Panasonic Industrial Devices SUNX Co., Ltd. 2014
28
Mounting
Step 4 Choose either the rear mounting bracket or the side mounting bracket.
<In case of rear mounting>
Bracket B
Main body
Rear mounting
bracket
Bracket A
<In case of side mounting>
Bracket B
Main body
Side mounting
bracket
Bracket A
Step 5 Secure bracket A, bracket B, and either the rear mounting bracket or side mounting
bracket in place with a hexagon-socket head bolt [M3 (length: 6mm)].
The tightening torque should be 0.5N•m.
<In case of rear mounting>
Main body
Hexagon-socket head bolt
[M3 (length: 6mm)]
<In case of side mounting>
Main body
Hexagon-socket head bolt
[M3 (length: 6mm)]
Step 6
Temporarily secure a hexagon head bolt [M5 (purchase separately)] to the mounting surface.
Step 7 Slide the device so that the rear mounting bracket or side mounting bracket fits around
the hexagon head bolt.
<In case of rear mounting>
Main body
Hexagon head bolt
[M5 (purchase separately)]
Hexagon head bolt
[M5 (purchase separately)]
Main body
<In case of side mounting>
Note:
SF4B-H□C□
: 48 beam channels or more,
SF4B-A□C□
: 24 beam channels or more require intermediate
supporting bracket for use with utility mounting bracket
MS-SF4BC-4
(optional).
SF4B-H40C
□,
SF4B-H48C
□,
SF4B-H56C
□,
SF4B-A20C
□,
SF4B-A24C
□,
SF4B-A28C
□: 1 set
SF4B-H64C
□,
SF4B-H72C
□,
SF4B-H80C
□,
SF4B-H88C
□,
SF4B-H96C
□,
SF4B-A32C
□,
SF4B-A36C
□,
SF4B-A40C
□,
SF4B-A44C
□,
SF4B-A48C
□: 2 sets
Ramco National
800-280-6933 | nsales@ramcoi.com