Function
<Timing chart (Normal)>
Light
received
Light
blocked
ON
ON
OFF
OFF
Light received
status
External device
monitor input
Control output
(OSSD 1 / 2)
300ms or less
300ms or less
90ms or less
14ms or less
The setting time of the device monitor is300ms or less. Exceeding 300ms turns the device into
lockout status. It can be set within 100 to 600ms (unit: 10ms) by using the handy controller
(
SFB-HC
) (optional).
<Timing chart (Error 1)>
Light
received
Light
blocked
ON
ON
OFF
OFF
Light received
status
External device
monitor input
Control output
(OSSD 1 / 2)
300ms
Lockout state
14ms or less
<Timing chart (Error 2)>
Light
received
Light
blocked
ON
ON
OFF
OFF
Light received
status
External device
monitor input
Control output
(OSSD 1 / 2)
90ms or less
300ms
Lockout state