SF4C Safety light curtain
6.2 Receiver-Related Problems
109
Error
Cause
Remedy
The auxiliary
output wire
(
g
reen/blac
k) and the external
device monitor
input wire
(
g
reen) are
not wired.
Connect the auxiliary output wire
(
g
reen/black) and the
external device monitor input wire
(
g
reen).
The external
device monitor
function is active
The auxiliary
output wire is not
correctly
operated.
Check if the auxiliary output wire is
disconnected or short-circuited.
[Digital error indicator: ]
Supply voltage error
The specified voltage is not supplied.
Check the wiring status, the supply
voltage, and the power supply
capacity.
[Digital error indicator: ]
Emitter error
The emitter is in lockout state.
Check the error indicator (yellow)
of the emitter.
[Digital error indicator: ]
Effect from noise/power supply or
failure of internal circuit
Affected by noise.
The internal circuit is broken.
Check the noise status of this
device. If the error cannot be
solved, contact SUNX.
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
mailbox@sentronic.com
www.sentronic.com
Produkte, Support und Service
SENTRONIC
AG