Before Using this Device
SF4C Safety light curtain
26
1.
2.
3.
Procedure
1. Loosen the M3 countersunk head screw (with anti-loosening agent, length
4mm) which is attached to the back of the device
2. Rotate the bracket to adjust the installation direction of emitter and receiver
3. Tighten the M3 countersunk head screw
The tightening torque should be 0,3N•m or less.
SF4C
Mountable in three directions
Standard mounting bracket
MS-SFC-1 (Accessory)
M3 countersunk head screw (with
anti-loosening agent, length 4mm)
4. Install the standard mounting brackets on the mounting surface with two
hexagon-socket head bolts (M5)
2.5.2 Mounting with Multifunctional Mounting Bracket MS-SFC-3 (optional)
The following procedure shows how to mount the safety light curtain with the multifunctional
mounting bracket MS-SFC-3.
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
mailbox@sentronic.com