2.5 Mounting
27
1.
2.
3.
Procedure
1. Remove the M3 countersunk head screw with anti-loosening agent (length
4mm) which is attached to the back of the device
SF4C
M3 countersunk head screw with
anti-loosening agent (length 4mm)
2. Then remove the standard mounting bracket MS-SFC-1
3. Mount the multifunctional mounting bracket using the M3 countersunk head
screw with anti-loosening agent (length 4mm) (accessory of the
multifunctional mounting bracket). The tightening torque should be 0.3N·m
M3 countersunk head screw with
anti-loosening agent (length 4mm)
(Accessory of
multifunctional mounting
bracket)
Multifunctional mounting
bracket (MS-SFC-3, optional)
Part B
Part A